The DOI matches its Crossref record.
PID controller adjustment using chaotic optimisation algorithm for multi-area load frequency control
Abstract
The early aim of the automatic generation control is to regulate the power output of the electrical generator within a prescribed area in response to changes in system frequency, tie-line loading, so as to maintain the scheduled system frequency and interchange with the other areas with predetermined limits. The purpose of this study is to propose a PID optimised by the lozi map-based chaotic algorithm (LCOA) to solve the load-frequency control (LFC) problem. The PIDs tuned by the LCOA are used in each area for a two-area power system. The simulation results are used to demonstrate the effectiveness and performance of the proposed controller. It is shown that optimised PID is able to solve the LFC problem and also the performance of the system in each area is satisfactory. In addition, a comparative study is carried out between the results obtained from PID tuned by the LCOA and the other optimisation algorithms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Load frequency control of interconnected power system using grey wolf optimization
Guha, D., Roy, P. K., & Banerjee, S. (2016) · Swarm and Evolutionary Computation · doi:10.1016/j.swevo.2015.10.004 · Cited by 396
Alhelou, H. H., Hamedani-Golshan, M.-E., Zamani, R., Heydarian-Forushani, E., & Siano, P. (2018) · Energies · doi:10.3390/en11102497 · Cited by 349
Fractional order PID controller for load frequency control
Sondhi, S., & Hote, Y. V. (2014) · Energy Conversion and Management · doi:10.1016/j.enconman.2014.05.091 · Cited by 281
Sahu, B. K., Pati, S., Mohanty, P. K., & Panda, S. (2015) · Applied Soft Computing · doi:10.1016/j.asoc.2014.11.027 · Cited by 261
Mohammadikia, R., & Tavakoli‐Kakhki, M. (2025) · Asian Journal of Control · doi:10.1002/asjc.3538 · Cited by 1
Metadata
- Authors
- Farahani, M., Ganjefar, S., & Alizadeh, M.
- Venue
- IET Control Theory & Applications
- Published
- 2012-09-06
- Volume
- 6
- Issue
- 13
- Pages
- 1984-1992
- ISSN
- 1751-8644 (ISSN-L)
- 1751-8652
- OpenAlex
- W2162463244
- Cited by
- 158
- References
- 0
- FWCI
- 3.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.