Pattern identification for eccentricity fault diagnosis in permanent magnet synchronous motors using stator current monitoring
The DOI matches its Crossref record.
Abstract
A novel theoretical scrutiny is presented here, which extracts eccentricity fault signatures by monitoring the stator current in permanent magnet synchronous motors (PMSMs). In this analysis, effects of the stator slots and saturation are taken into account for static and dynamic eccentricity fault detection. Eccentricity signatures are utilised to introduce a particular frequency pattern, and amplitude of side-band components at proposed frequencies is employed as a proper index for eccentricity fault recognition. Competence of the nominated index to detect eccentricity, its type and its degree is investigated in faulty PMSM with different load levels. Hence, time-stepping finite-element method is used to model faulty PMSM and calculate stator currents for processing and obtaining aforementioned proposed index. The relation between the nominated index, static and dynamic eccentricity degrees is determined by a mutual information criterion. So, a white Gaussian noise is added to the simulated current and robustness of the proposed index is analysed with respect to the noise variance. Finally, the type and the degree of eccentricity are predicted using support vector machine as a classifier. The classification results indicate that the proposed features can estimate the eccentricity degree and its type. The simulation results are verified by the experimental results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Faults and Diagnosis Methods of Permanent Magnet Synchronous Motors: A Review
Chen, Y., Liang, S., Li, W., Liang, H., & Wang, C. (2019) · Applied Sciences · doi:10.3390/app9102116 · Cited by 194
Park, Y., Fernandez, D., Lee, S. B., Hyun, D., Jeong, M., Kommuri, S. K., Cho, C., Diaz Reigosa, D., & Briz, F. (2019) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2018.2886772 · Cited by 116
“MCSA can provide remote, online monitoring from the inverter using existing sensors, and is independent of the motor mathematical model [3], [4], [7]–[10].”
BackgroundKarami, M., Mariun, N., Rezazadeh Mehrjou, M., Ab Kadir, M. Z. A., Misron, N., & Mohd Radzi, M. A. (2014) · Mathematical Problems in Engineering · doi:10.1155/2014/132647 · Cited by 31
“The permeance of an air-gap contains stator slotting permeance and smooth rotor in PMSM which can be written as [26]”
BackgroundAn effective method for detection of stator fault in PMSM with 1D-LBP
Mi̇naz, M. R. (2020) · ISA Transactions · doi:10.1016/j.isatra.2020.07.013 · Cited by 23
Metadata
- Authors
- Ebrahimi, B. M., Faiz, J., & Araabi, B. N.
- Venue
- IET Electric Power Applications
- Published
- 2010-07-05
- Volume
- 4
- Issue
- 6
- Pages
- 418-430
- ISSN
- 1751-8660 (ISSN-L)
- 1751-8679
- OpenAlex
- W2049522343
- Cited by
- 65
- References
- 0
- FWCI
- 5.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Pattern identification for eccentricity fault diagnosis in permanent magnet synchronous motors using stator current monitoring. https://app.cochat.ai/papers/10.1049/iet-epa.2009.0149
- The paper
- Ebrahimi, B. M., Faiz, J., & Araabi, B. N. (2010). Pattern identification for eccentricity fault diagnosis in permanent magnet synchronous motors using stator current monitoring. IET Electric Power Applications. https://doi.org/10.1049/iet-epa.2009.0149
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.