The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Analytical approach for placement and sizing of distributed generation on distribution systems
Abstract
An analytical method for placement and sizing of distributed generation on power distribution systems for loss reduction is introduced. The proposed analytical method is developed based on a new formulation for the power flow problem, which is non‐iterative, direct, and involves no convergence issues even for systems with high R / X branch ratios. Further, this power flow solution is extremely useful whenever fast and repetitive power flow estimations are required. A priority list based on loss sensitivity factors is developed to determine the optimal locations of the candidate distributed generation units. Sensitivity analysis is performed to estimate the optimal size and power factor of the candidate distributed generation units. Various types of distributed generators (DGs) have been dealt with and viable solutions are proposed to reduce total system loss. The proposed method has been tested on 33‐bus and 69‐bus distribution systems, which are extensively used as examples in solving the placement and sizing problem of DGs. Exhaustive power flow routines are also performed to verify the sizes obtained by the analytical method. The test results show that the proposed analytical method could lead to optimal or near‐optimal solution, while requiring lower computational effort.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Optimal capacitor placement on radial distribution systems
Baran, M. E., & Wu, F. F. (1989) · IEEE Transactions on Power Delivery · doi:10.1109/61.19265 · Cited by 2,062
Distribution System Modeling and Analysis
Kersting, W. (2012) · Electric Power Engineering Series · doi:10.1201/b12056-31 · Cited by 1,241
Cited by
Ehsan, A., & Yang, Q. (2018) · Applied Energy · doi:10.1016/j.apenergy.2017.10.106 · Cited by 524
Optimal Allocation of Distributed Generation Using Hybrid Grey Wolf Optimizer
Sanjay, R., Jayabarathi, T., Raghunathan, T., Ramesh, V., & Mithulananthan, N. (2017) · IEEE Access · doi:10.1109/access.2017.2726586 · Cited by 272
Mulenga, E., Bollen, M. H. J., & Etherden, N. (2020) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2019.105445 · Cited by 271
Zubo, R. H. A., Mokryani, G., Rajamani, H.-S., Aghaei, J., Niknam, T., & Pillai, P. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.10.036 · Cited by 218
Metadata
- Authors
- Elsaiah, S., Benidris, M., & Mitra, J.
- Venue
- IET Generation, Transmission & Distribution
- Published
- 2014-06
- Volume
- 8
- Issue
- 6
- Pages
- 1039-1049
- ISSN
- 1751-8687 (ISSN-L)
- 1751-8695
- OpenAlex
- W2011456663
- Cited by
- 163
- References
- 2
- FWCI
- 8.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Analytical approach for placement and sizing of distributed generation on distribution systems. https://app.cochat.ai/papers/10.1049/iet-gtd.2013.0803
- The paper
- Elsaiah, S., Benidris, M., & Mitra, J. (2014). Analytical approach for placement and sizing of distributed generation on distribution systems. IET Generation, Transmission & Distribution. https://doi.org/10.1049/iet-gtd.2013.0803
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.