The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Post‐disturbance transient stability assessment of power systems by a self‐adaptive intelligent system
Abstract
Intelligent system (IS) using synchronous phasor measurements for transient stability assessment (TSA) has received continuous interests recently. For post‐disturbance TSA, one pivotal concern is the response time, which was reported in the literature as a fixed value ranging from 4 cycles to 3 s after fault clearance. Since transient instability can develop very fast, there is a pressing need for faster response speed. This paper develops a novel IS to balance the response speed and accuracy requirements. A set of classifiers are sequentially organised, each is an ensemble of extreme learning machines (ELMs), whose inputs are post‐disturbance generator voltage trajectories and outputs are the classification on the stable/unstable status of the post‐disturbance system and an evaluation of the credibility of the classification. A self‐adaptive TSA decision‐making mechanism is designed to progressively adjust the response time, such that the IS can do the classification faster, thereby allowing more time for emergency controls. The ELM ensemble classifiers can also be updated by on‐line pre‐disturbance TSA results due to its very fast learning speed. Case studies on the New England system and IEEE 50‐machine system have validated the high efficiency and accuracy of the IS.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Breiman, L. (2001) · Machine Learning · doi:10.1023/a:1010933404324 · Cited by 133,538
Hansen, L. K., & Salamon, P. (1990) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.58871 · Cited by 4,260
Cited by
Intelligent Time-Adaptive Transient Stability Assessment System
Yu, J. J. Q., Hill, D. J., Lam, A. Y. S., Gu, J., & Li, V. O. K. (2018) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2017.2707501 · Cited by 370
Shi, Z., Yao, W., Li, Z., Zeng, L., Zhao, Y., Zhang, R., Tang, Y., & Wen, J. (2020) · Applied Energy · doi:10.1016/j.apenergy.2020.115733 · Cited by 327
Self-citation
Metadata
- Authors
- Zhang, R., Xu, Y., Dong, Z. Y., & Wong, K. P.
- Venue
- IET Generation, Transmission & Distribution
- Published
- 2015-02
- Volume
- 9
- Issue
- 3
- Pages
- 296-305
- ISSN
- 1751-8687 (ISSN-L)
- 1751-8695
- OpenAlex
- W1966534617
- Cited by
- 163
- References
- 2
- FWCI
- 7.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Post‐disturbance transient stability assessment of power systems by a self‐adaptive intelligent system. https://app.cochat.ai/papers/10.1049/iet-gtd.2014.0264
- The paper
- Zhang, R., Xu, Y., Dong, Z. Y., & Wong, K. P. (2015). Post‐disturbance transient stability assessment of power systems by a self‐adaptive intelligent system. IET Generation, Transmission & Distribution. https://doi.org/10.1049/iet-gtd.2014.0264
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.