Multiple distributed generation units allocation in distribution network for loss reduction based on a combination of analytical and genetic algorithm methods
Open accessThe DOI matches its Crossref record.
Abstract
Many methods have been proposed to determine the optimal location and capacities of distributed generation (DG) units to reach the lowest value for system losses. In this study, the combination of analytical and genetic algorithm methods is used for optimal allocation of multiple DGs in a distribution network to minimise the system losses. This combination guarantees the convergence accuracy and speed in multiple DG units allocation. In this study, the DGs active power, power factor, and location are simultaneously considered during distribution network losses minimisation. The utility will dictate only the maximum DG power generation if the DG is installed by DG owner. However, both of the size and the location of DG will be determined by the utility if the DG is installed by it. The proposed method is applied to 33‐bus and 69‐bus test distribution systems. Simulation results show that the proposed method results in lower losses compared with the other methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ehsan, A., & Yang, Q. (2018) · Applied Energy · doi:10.1016/j.apenergy.2017.10.106 · Cited by 524
Review of Metaheuristic Optimization Algorithms for Power Systems Problems
Nassef, A. M., Abdelkareem, M. A., Maghrabie, H. M., & Baroutaji, A. (2023) · Sustainability · doi:10.3390/su15129434 · Cited by 177
“…the i th unit fuel cost which is given in Equation (27), S i ( t ) is the i th unit start-up cost, which is presented as S i ( t ) = Sh i i f T i , of f ( t ) ≤ T i , Down + T i , cold Sc i i f T i , of f ( t ) > T i , Down + T i , cold (28) where Sh i and Sc i are the hot and cold start-up…”
A Review of the Tools and Methods for Distribution Networks’ Hosting Capacity Calculation
Zain ul Abideen, M., Ellabban, O., & Al-Fagih, L. (2020) · Energies · doi:10.3390/en13112758 · Cited by 161
“The most common techniques are Particle Swarm Optimization (PSO) [62,68] as it is easy to implement, Artificial Bee Colony (ABC) [69] because of its fast convergence, Robust optimization [70–72] as it incorporates the uncertainty of DG output/size/location into the calculation and Genetic Algorithm (GA) [73] since it…”
MethodUmoh, V., Davidson, I., Adebiyi, A., & Ekpe, U. (2023) · Energies · doi:10.3390/en16083609 · Cited by 71
Ali, A., Mahmoud, K., Raisz, D., & Lehtonen, M. (2021) · IEEE Systems Journal · doi:10.1109/jsyst.2020.2982467 · Cited by 50
Metadata
- Authors
- Vatani, M., Solati Alkaran, D., Sanjari, M. J., & Gharehpetian, G. B.
- Venue
- IET Generation, Transmission & Distribution
- Published
- 2016-01
- Volume
- 10
- Issue
- 1
- Pages
- 66-72
- ISSN
- 1751-8687 (ISSN-L)
- 1751-8695
- OpenAlex
- W2296510263
- Cited by
- 155
- References
- 0
- FWCI
- 5.61
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.