The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Optimal sizing and sitting of DG with load models using soft computing techniques in practical distribution system
Abstract
In the deregulated power market environment, distributed generation (DG) is an effective approach to manage performance, operation and control of the distribution system. Methods available in the literature for DG planning are often not able to simultaneously provide technical and economical benefits. Therefore an effective methodology is developed to improve the technical as well as economical benefits as compared with the existing approaches. This study reports the optimal installation of multi‐DG in the standard 33‐bus, 69‐bus radial distribution systems and 54‐bus practical radial distribution system. Several performance evaluation indices such as active and reactive power loss indices, voltage deviation index, reliability index and shift factor indices are used to develop a novel multi‐objective function (MOF). A new set of equations is developed for representing different practical load models. A novel MOF has been solved to find optimal sizing and placement of DGs using genetic algorithm and particle swarm optimisation technique. The comparative result analysis is also discussed for both techniques. The result analysis reveals that system losses, energy not supplied, system MVA intakes are reduced, whereas available transfer capability, voltage profile, reliability and cost benefits are improved for the case with‐DGs in the distribution system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new optimizer using particle swarm theory
Eberhart, R., & Kennedy, J. (2002) · MHS'95. Proceedings of the Sixth International Symposium on Micro Machine and Human Science · doi:10.1109/mhs.1995.494215 · Cited by 16,067
Cited by
Review of hybrid renewable energy systems with comparative analysis of off-grid hybrid system
Sawle, Y., Gupta, S. C., & Bohre, A. K. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.06.033 · Cited by 339
Self-citationAfzali, P., Hosseini, S. A., & Peyghami, S. (2024) · Applied Sciences · doi:10.3390/app142412042 · Cited by 29
(2018) · Digital Commons - DU (University of Denver) · Cited by 3
Metadata
- Authors
- Bohre, A. K., Agnihotri, G., & Dubey, M.
- Venue
- IET Generation, Transmission & Distribution
- Published
- 2016-08
- Volume
- 10
- Issue
- 11
- Pages
- 2606-2621
- ISSN
- 1751-8687 (ISSN-L)
- 1751-8695
- OpenAlex
- W2344807340
- Cited by
- 158
- References
- 1
- FWCI
- 6.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optimal sizing and sitting of DG with load models using soft computing techniques in practical distribution system. https://app.cochat.ai/papers/10.1049/iet-gtd.2015.1034
- The paper
- Bohre, A. K., Agnihotri, G., & Dubey, M. (2016). Optimal sizing and sitting of DG with load models using soft computing techniques in practical distribution system. IET Generation, Transmission & Distribution. https://doi.org/10.1049/iet-gtd.2015.1034
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.