Efficient frequency controllers for autonomous two‐area hybrid microgrid system using social‐spider optimiser
The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
In this study, an efficient load frequency controller (LFC) for standalone two‐area hybrid microgrid system (HμGS) is addressed. Social‐spider optimiser (SSO) is applied to fine tune the proposed proportional–integral–derivative (PID) controllers by generating their optimal settings. The integral time multiplied summation of absolute deviations and the gains of PID controllers define the fitness function and control variables, respectively. The performance of the proposed SSO‐based method is demonstrated on an isolated HμGS complete with variety of energy storage systems under number of scenarios. The scenarios include load fluctuations, variations in wind speed, and sun irradiance employing real site measurements. In this study, photovoltaic generating arrays and wind turbine generators are not participating in system frequency regulations due the proposal of their maximum power tracking operation strategy. The signatures of time‐domain dynamic responses and cropped numerical results ascertain that the proposed SSO‐based LFC scheme is promising in diminuting the signal deviations and in short time. Further validations for cropped results produced by SSO are made compared with powerful optimisation tool such as genetic algorithm which signify the tuned PID gains.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A swarm optimization algorithm inspired in the behavior of the social-spider
Cuevas, E., Cienfuegos, M., Zaldívar, D., & Pérez-Cisneros, M. (2013) · Expert Systems with Applications · doi:10.1016/j.eswa.2013.05.041 · Cited by 573
Pandey, S. K., Mohanty, S. R., & Kishor, N. (2013) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2013.04.029 · Cited by 561
Load frequency control strategies: A state-of-the-art survey for the researcher
Shayeghi, H., Shayanfar, H. A., & Jalili, A. (2008) · Energy Conversion and Management · doi:10.1016/j.enconman.2008.09.014 · Cited by 550
Das, D. C., Roy, A. K., & Sinha, N. (2012) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2012.05.025 · Cited by 522
Optimization of micro-grid system using MOPSO
Borhanazad, H., Mekhilef, S., Ganapathy, V., Modiri-Delshad, M., & Mirtaheri, A. (2014) · Renewable Energy · doi:10.1016/j.renene.2014.05.006 · Cited by 510
A social spider algorithm for global optimization
Yu, J. J. Q., & Li, V. O. K. (2015) · Applied Soft Computing · doi:10.1016/j.asoc.2015.02.014 · Cited by 416
A survey on control of electric power distributed generation systems for microgrid applications
Bouzid, A. M., Guerrero, J. M., Cheriti, A., Bouhamida, M., Sicard, P., & Benghanem, M. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.01.016 · Cited by 401
Stability analysis for stochastic hybrid systems: A survey
Teel, A. R., Subbaraman, A., & Sferlazza, A. (2014) · Automatica · doi:10.1016/j.automatica.2014.08.006 · Cited by 330
Ray, P. K., Mohanty, S. R., & Kishor, N. (2011) · Energy Conversion and Management · doi:10.1016/j.enconman.2010.11.011 · Cited by 222
Shankar, R., Chatterjee, K., & Bhushan, R. (2016) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2015.12.029 · Cited by 179
Yang, J. B., Zeng, Z., Tang, Y., Yan, J., He, H., & Wu, Y. (2015) · Energies · doi:10.3390/en8032145 · Cited by 162
A hybrid DE–PS algorithm for load frequency control under deregulated power system with UPFC and RFB
Sahu, R. K., Gorripotu, T. S., & Panda, S. (2015) · Ain Shams Engineering Journal · doi:10.1016/j.asej.2015.03.011 · Cited by 143
Ouadfel, S., & Ahmed, A. T. (2016) · Expert Systems with Applications · doi:10.1016/j.eswa.2016.02.024 · Cited by 143
Chidambaram, I. A., & Paramasivam, B. (2013) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2013.02.004 · Cited by 138
Robust PI control of smart controllable load for frequency stabilization of microgrid power system
Nandar, C. S. A. (2012) · Renewable Energy · doi:10.1016/j.renene.2012.10.032 · Cited by 115
Goya, T., Omine, E., Kinjyo, Y., Senjyu, T. S., Yona, A., Urasaki, N., & Funabashi, T. (2011) · IET Renewable Power Generation · doi:10.1049/iet-rpg.2010.0083 · Cited by 112
El‐Hameed, M. A., & El‐Fergany, A. A. (2016) · IET Generation Transmission & Distribution · doi:10.1049/iet-gtd.2016.0699 · Cited by 77
Self-citationSocial-Spider Optimization-based Support Vector Machines applied for energy theft detection
Pereira, D. R., Pazoti, M. A., Pereira, L. A. M., Rodrigues, D., Ramos, C. C. O., de Souza, A. N., & Papa, J. P. (2015) · Computers & Electrical Engineering · doi:10.1016/j.compeleceng.2015.11.001 · Cited by 63
Kavousi‐Fard, A., Abbasi, A., Rostami, M.-A., & Khosravi, A. (2015) · Energy · doi:10.1016/j.energy.2015.10.055 · Cited by 51
Coordinated control of distributed energy resources to support load frequency control
Pandi, V. R., Al‐Hinai, A., & Feliachi, A. (2015) · Energy Conversion and Management · doi:10.1016/j.enconman.2015.08.046 · Cited by 36
Cited by
Latif, A., Hussain, S. M. S., Das, D. C., & Ustun, T. S. (2020) · Applied Energy · doi:10.1016/j.apenergy.2020.114858 · Cited by 183
Kumar, R., & Sharma, V. K. (2021) · International Journal of Numerical Modelling: Electronic Networks, Devices and Fields · doi:10.1002/jnm.2802 · Cited by 14
“The parameterw1 balance the target by using Equation (21).”
Metadata
- Authors
- El‐Fergany, A. A., & El‐Hameed, M. A.
- Venue
- IET Generation, Transmission & Distribution
- Published
- 2017-02
- Volume
- 11
- Issue
- 3
- Pages
- 637-648
- ISSN
- 1751-8687 (ISSN-L)
- 1751-8695
- OpenAlex
- W2481662626
- Cited by
- 208
- References
- 20
- FWCI
- 5.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).