Zero-voltage switching bi-directional power electronic transformer
The DOI matches its Crossref record.
Abstract
In this study, a bi-directional power flow zero-voltage switching (ZVS) power electronic transformer (PET) with phase shift modulation controller (PSM) is proposed. The PET contains input full-bridge active rectifier (FBAR), full-bridge DC-link inverter (FBDCI), high-frequency isolating transformer (HFIT), cycloconverter and output filter. FBDCI switches operate under ZVS condition. In addition, ZVS commutation of both cycloconverter bi-directional switches and FBAR switches are achieved. Dynamic voltage regulation is obtained without utilising energy storage elements. Therefore good efficiency can be achieved as a result of ZVS operation together with the absence of energy storage elements. The values of output filter are calculated to provide soft switching operation and voltage regulation. Based on the simulation and experimental results, the steady-state operation principles of the PET are described. Experimental results from a laboratory prototype with specification of 110 V/50 Hz input to 24 V/50 Hz output are presented to verify feasibility of the proposed PET.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Review of Solid-State Transformer Technologies and Their Application in Power Distribution Systems
She, X., Huang, A. Q., & Burgos, R. (2013) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2013.2277917 · Cited by 1,164
Hybrid ac/dc microgrids—Part I: Review and classification of topologies
Unamuno, E., & Barrena, J. A. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.07.194 · Cited by 399
Abu-Siada, A., Budiri, J., & Abdou, A. (2018) · Electronics · doi:10.3390/electronics7110298 · Cited by 69
“This was attempted in [24] by including the h gh-frequency transformer in th second stage and using a cycloconverter for a direct AC–AC conversion.”
BackgroundMethodInfluentialPower flow control scheme for multiport power electronics transformers
Zhang, H., Jing, L., Wu, X., Jiang, J., Wickramasinghe, H. R., & Konstantinou, G. (2018) · High Voltage · doi:10.1049/hve.2018.5034 · Cited by 8
Metadata
- Authors
- Sabahi, M., Hosseini, S. H., Sharifian, M. B., Goharrizi, A. Y., & Gharehpetian, G. B.
- Venue
- IET Power Electronics
- Published
- 2010-09
- Volume
- 3
- Issue
- 5
- Pages
- 818-828
- ISSN
- 1755-4535 (ISSN-L)
- 1755-4543
- OpenAlex
- W1976852391
- Cited by
- 48
- References
- 0
- FWCI
- 1.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Zero-voltage switching bi-directional power electronic transformer. https://app.cochat.ai/papers/10.1049/iet-pel.2008.0070
- The paper
- Sabahi, M., Hosseini, S. H., Sharifian, M. B., Goharrizi, A. Y., & Gharehpetian, G. B. (2010). Zero-voltage switching bi-directional power electronic transformer. IET Power Electronics. https://doi.org/10.1049/iet-pel.2008.0070
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.