The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Fuzzy logic controlled shunt active power filter for power quality improvement
Abstract
The simulation and experimental study of a fuzzy logic controlled, three-phase shunt active power filter to improve power quality by compensating harmonics and reactive power required by a nonlinear load. The advantage of fuzzy control is that it is based on a linguistic description and does not require a mathematical model of the system. The fuzzy control scheme is realised on an inexpensive dedicated micro-controller (INTEL 8031) based system. The compensation process is based on sensing line currents only, an approach different from conventional methods, which require harmonics or reactive volt-ampere requirement of the load. The performance of the fuzzy logic controller is compared with a conventional PI controller. The dynamic behavior of the fuzzy controller is found to be better than the conventional PI controller. PWM pattern generation is based on carrierless hysteresis based current control to obtain the switching signals. Various simulation and experimental results are presented under steady state and transient conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fuzzy logic in control systems: fuzzy logic controller. I
Lee, C. C. (1990) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/21.52551 · Cited by 5,616
Power Electronics: Converters, Applications and Design
Mohan, N., Undeland, T. M., & Robbins, W. P. (1989) · Cited by 4,771
Akagi, H., Kanazawa, Y., & Nabae, A. (1984) · IEEE Transactions on Industry Applications · doi:10.1109/tia.1984.4504460 · Cited by 3,377
A review of active filters for power quality improvement
Singh, B., Al-Haddad, K., & Chandra, A. (1999) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.793345 · Cited by 2,361
Survey of active power line conditioning methodologies
Grady, W. M., Samotyj, M. J., & Noyola, A. H. (1990) · IEEE Transactions on Power Delivery · doi:10.1109/61.57998 · Cited by 562
Raviraj, V. S. C., & Sen, P. C. (1997) · IEEE Transactions on Industry Applications · doi:10.1109/28.568018 · Cited by 292
Raviraj, V. S. C., & Sen, P. C. (2002) · IAS '95. Conference Record of the 1995 IEEE Industry Applications Conference Thirtieth IAS Annual Meeting · doi:10.1109/ias.1995.530502 · Cited by 277
A control algorithm for three-phase three-wired active power filters under nonideal mains voltages
Huang, S., & Wu, J. (1999) · IEEE Transactions on Power Electronics · doi:10.1109/63.774215 · Cited by 126
Design and Performance Of Active Power Filters
Thomas, T., Haddad, K. A., Joós, G., et al. (1998) · IEEE Industry Applications Magazine · doi:10.1109/2943.715505 · Cited by 98
Cited by
Agrawal, S., Palwalia, D. K., & Kumar, M. (2022) · IETE Journal of Research · doi:10.1080/03772063.2019.1617198 · Cited by 50
Metadata
- Authors
- Jain, S. K., Agrawal, P., & Gupta, H. O.
- Venue
- IEE Proceedings - Electric Power Applications
- Published
- 2002-09-10
- Volume
- 149
- Issue
- 5
- Pages
- 317-328
- ISSN
- 1350-2352 (ISSN-L)
- 1359-7043
- OpenAlex
- W2066948779
- Cited by
- 341
- References
- 9
- FWCI
- 4.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.