The DOI matches its Crossref record.
On the control of photovoltaic maximum power point tracker via output parameters
Abstract
A new approach for tracking the maximum power point of photovoltaic arrays is presented. The maximum power point tracker output voltage and current are used for control purposes, rather than for its input voltage and current. It is shown that using the output parameters simplifies the maximum power point tracker controller. Moreover, using this approach, only one out of the two output parameters needs to be sensed. This observation is general and applies regardless of the power stage or the realisation control algorithm. Contrary to what might have previously been assumed, it is theoretically shown that the MPPT control that uses a single output control parameter applies to nearly all practical load types, regardless of the load nature.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Comparison of Photovoltaic Array Maximum Power Point Tracking Techniques
Esram, T., & Chapman, P. L. (2007) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2006.874230 · Cited by 5,425
A Comparative Study on Maximum Power Point Tracking Techniques for Photovoltaic Power Systems
Subudhi, B., & Pradhan, R. (2013) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2012.2202294 · Cited by 1,867
Vullers, R. J. M., van Schaijk, R., Doms, I., Van Hoof, C., & Mertens, R. (2009) · Solid-State Electronics · doi:10.1016/j.sse.2008.12.011 · Cited by 886
Reliability Issues in Photovoltaic Power Processing Systems
Petrone, G., Spagnuolo, G., Teodorescu, R., Veerachary, M., & Vitelli, M. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.924016 · Cited by 579
Maximum power point tracking (MPPT) techniques: Recapitulation in solar photovoltaic systems
Verma, D., Nema, S., Shandilya, A. M., & Dash, S. K. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.10.068 · Cited by 420
Predictive & Adaptive MPPT Perturb and Observe Method
Femia, N., Granozio, D., Petrone, G., Spagnuolo, G., & Vitelli, M. (2007) · IEEE Transactions on Aerospace and Electronic Systems · doi:10.1109/taes.2007.4383584 · Cited by 406
The most used MPPT algorithms: Review and the suitable low-cost embedded board for each algorithm
Motahhir, S., El Hammoumi, A., & El Ghzizal, A. (2020) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2019.118983 · Cited by 392
Ali, A., Almutairi, K., Padmanaban, S., Tirth, V., Algarni, S., Irshad, K., Islam, S., Zahir, M. H., Shafiullah, M., & Malik, M. Z. (2020) · IEEE Access · doi:10.1109/access.2020.3007710 · Cited by 282
Metadata
- Authors
- Shmilovitz, D.
- Venue
- IEE Proceedings - Electric Power Applications
- Published
- 2005-03
- Volume
- 152
- Issue
- 2
- Pages
- 239-248
- ISSN
- 1350-2352 (ISSN-L)
- 1359-7043
- OpenAlex
- W2003936123
- Cited by
- 236
- References
- 0
- FWCI
- 5.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.