Creatinine clearance as a measure of GFR in screenees for the African- American Study of Kidney Disease and Hypertension pilot study
Open accessThe DOI matches its Crossref record.
Abstract
Serum creatinine and endogenous creatinine clearance (CrCl) are widely used measures of renal function. This study compares the precision, bias, and sources of error in using different CrCl measures to estimate the glomerular filtration rate (GFR) in 118 men and women screened for the African-American Study of Kidney Disease and Hypertension (AASK) pilot study. We measured serum creatinine, 24-hour CrCl, and CrCl during timed clearance periods conducted simultaneously with an 125I-iothalamate GFR study. Serum creatinine was measured using two different kinetic rate Jaffe methods (CX3 and Hitachi). After standardization for body surface area, the different measures of renal function available for each individual were compared with the 125I-iothalamate GFR simultaneous to the CrCl. In a subset of 50 participants, the CrCl measures were compared with a follow-up GFR (fGFR). The mean 125I-iothalamate GFR was 65.2 (SD, 26.4), with a range of 11 to 122 mL/min/1.73 m2. The mean +/- SD percentage differences from the GFR were -9%+/-22% for the Cockcroft-Gault estimated CrCl, 1%+/-29% for the 24-hour CrCl, and 8%+/-16% for the CX3 simultaneous CrCl. The Hitachi method overestimated serum creatinine and underestimated GFR. Compared with an fGFR, the mean +/- SD differences were 2%+/-19% for the first GFR, -6%+/-20% for the Cockcroft-Gault estimated CrCl, 10%+/-28% for the 24-hour CrCl, and 14%+/-29% for the CX3 simultaneous CrCl. Thus, the increased precision with which the timed CrCl predicted its simultaneous GFR did not extend to improved ability to predict a future GFR. The fractional excretion of creatinine, measured as the ratio of the CX3 simultaneous CrCl to 125I-iothalamate clearance, increased with decreasing GFR but was lower than expected (mean +/- SD of 1.21+/-0.16 for GFRs between 20 and 40 mL/min/1.73 m2). The lower fractional excretion explains why the 24-hour and Cockcroft-Gault CrCls did not overestimate GFR, but the reasons for this lower excretion are uncertain. Creatinine assay specificity and calibration are important sources of variability that must be examined in any CrCl measure of GFR. We conclude that despite requiring substantially more time and effort, neither the outpatient 24-hour urine nor the timed CrCl offered increased precision over a calculation based on serum creatinine, sex, age, and weight in predicting GFR.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
KDIGO 2024 clinical practice guideline for the evaluation and management of chronic kidney disease
Stevens, P. E., Ahmed, S. B., Carrero, J. J., Foster, B., Francis, A., Hall, R. K., Herrington, W. G., Hill, G., Inker, L. A., Kazancıoğlu, R., et al. (2024) · Kidney International · doi:10.1016/j.kint.2023.10.018 · Cited by 8,530
Assessing Kidney Function — Measured and Estimated Glomerular Filtration Rate
Stevens, L. A., Coresh, J., Greene, T., & Levey, A. S. (2006) · New England Journal of Medicine · doi:10.1056/nejmra054415 · Cited by 2,952
Self-citationAgodoa, L. Y. (2001) · JAMA · doi:10.1001/jama.285.21.2719 · Cited by 944
Self-citationElevations of Inflammatory and Procoagulant Biomarkers in Elderly Persons With Renal Insufficiency
Shlipak, M. G., Fried, L. F., Crump, C., Bleyer, A. J., Manolio, T. A., Tracy, R. P., Furberg, C. D., & Psaty, B. M. (2003) · Circulation · doi:10.1161/01.cir.0000042700.48769.59 · Cited by 810
Shlipak, M. G., Fried, L. F., Cushman, M., Manolio, T. A., Peterson, D., Stehman-Breen, C., Bleyer, A., Newman, A., Siscovick, D., & Psaty, B. (2005) · JAMA · doi:10.1001/jama.293.14.1737 · Cited by 735
Coresh, J., Astor, B. C., McQuillan, G., Kusek, J., Greene, T., Van Lente, F., & Levey, A. S. (2002) · American Journal of Kidney Diseases · doi:10.1053/ajkd.2002.32765 · Cited by 717
Self-citationCoresh, J., Wei, G. L., McQuillan, G., Brancati, F. L., Levey, A. S., Jones, C., & Klag, M. J. (2001) · Archives of Internal Medicine · doi:10.1001/archinte.161.9.1207 · Cited by 587
Self-citationRenal insufficiency as a predictor of cardiovascular outcomes and mortality in elderly individuals
Fried, L. F., Shlipak, M. G., Crump, C., Kronmal, R. A., Bleyer, A. J., Gottdiener, J. S., Kuller, L. H., & Newman, A. B. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(03)00163-3 · Cited by 535
Lin, J., Knight, E. L., Hogan, M. L., & Singh, A. K. (2003) · Journal of the American Society of Nephrology · doi:10.1097/01.asn.0000088721.98173.4b · Cited by 413
Adult Reference Ranges for Serum Cystatin C, Creatinine and Predicted Creatinine Clearance
Finney, H., Newman, D. J., & Price, C. P. (2000) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1177/000456320003700101 · Cited by 287
Prediction equations to estimate glomerular filtration rate: an update
Manjunath, G., Sarnak, M. J., & Levey, A. S. (2001) · Current Opinion in Nephrology and Hypertension · doi:10.1097/00041552-200111000-00009 · Cited by 277
Hallan, S., Åsberg, A., Lindberg, M., & Johnsen, H. (2004) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2004.03.027 · Cited by 266
Kidney Disease, Race, and GFR Estimation
Levey, A. S., Titan, S. M., Powe, N. R., Coresh, J., & Inker, L. A. (2020) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.12791019 · Cited by 252
Self-citationRace, genetic ancestry, and estimating kidney function in CKD
Hsu, C.-Y., Yang, W., Parikh, R. V., Anderson, A. H., Chen, T. K., Cohen, D. L., He, J., Mohanty, M. J., Lash, J. P., Mills, K. T., et al. (2021) · New England Journal of Medicine · doi:10.1056/nejmoa2103753 · Cited by 241
Estimating kidney function in adults using formulae
Lamb, E. J., Tomson, C. R., & Roderick, P. J. (2005) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1258/0004563054889936 · Cited by 238
Unreferred chronic kidney disease: a longitudinal study
John, R., Webb, M., Young, A., & Stevens, P. E. (2004) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2003.12.046 · Cited by 238
Estimating GFR Among Participants in the Chronic Renal Insufficiency Cohort (CRIC) Study
Anderson, A. H., Yang, W., Hsu, C.-Y., Joffe, M. M., Leonard, M. B., Xie, D., Chen, J., Greene, T., Jaar, B. G., Kao, P., et al. (2012) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2012.04.012 · Cited by 237
Clase, C. M., Garg, A. X., & Kiberd, B. A. (2002) · Journal of the American Society of Nephrology · doi:10.1097/01.asn.0000013291.78621.26 · Cited by 223
“Though the importance of issues of measurement methodology and calibration in research studies has been recognized (40), the importance of these factors in the identification of low GFR in community practice has not previously been emphasized.”
BackgroundApplication of GFR-estimating equations in Chinese patients with chronic kidney disease
Zuo, L., Ma, Y.-C., Zhou, Y.-H., Wang, M., Xu, G.-B., & Wang, H.-Y. (2005) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2004.11.012 · Cited by 202
Methodological issues in studying the epidemiology of mild to moderate chronic renal insufficiency
Hsu, C.-Y., Chertow, G. M., & Curhan, G. C. (2002) · Kidney International · doi:10.1046/j.1523-1755.2002.00299.x · Cited by 196
“2 mg/dL higher than the CX3 analyzer (Beckman Instruments, Brea, CA, USA”
BackgroundAssessing renal function from creatinine measurements in adults with chronic renal failure
Walser, M. (1998) · American Journal of Kidney Diseases · doi:10.1053/ajkd.1998.v32.pm9669420 · Cited by 185
Ix, J. H., Mercado, N., Shlipak, M. G., Lemos, P. A., Boersma, E., Lindeboom, W., O'Neill, W. W., Wijns, W., & Serruys, P. W. (2005) · American Heart Journal · doi:10.1016/j.ahj.2004.10.010 · Cited by 182
Vickery, S., Stevens, P. E., Dalton, R. N., van Lente, F., & Lamb, E. J. (2006) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfl249 · Cited by 173
“The assay has been reported to have an average 6 mmol/l positive bias compared with a high-performance liquid chromatography (HPLC) procedure [16].”
MethodSelf-citationCardiovascular disease risk status in elderly persons with renal insufficiency
Shlipak, M. G., Fried, L. F., Crump, C., Bleyer, A. J., Manolio, T. A., Tracy, R. P., Furberg, C. D., & Psaty, B. M. (2002) · Kidney International · doi:10.1046/j.1523-1755.2002.00522.x · Cited by 170
“Inulin or iothalamate clearances are invasive and cumbersome, and 24-hour urine collections are very unreliabl”
BackgroundHsu, J., Johansen, K. L., Hsu, C.-Y., Kaysen, G. A., & Chertow, G. M. (2008) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.00090108 · Cited by 81
Metadata
- Authors
- Coresh, J., Toto, R., Kirk, K., Whelton, P., Massry, S., Jones, C., Agodoa, L., & Van Lente, F.
- Venue
- American Journal of Kidney Diseases
- Publisher
- Elsevier BV
- Published
- 1998-07
- Volume
- 32
- Issue
- 1
- Pages
- 32-42
- ISSN
- 0272-6386 (ISSN-L)
- OpenAlex
- W2048051429
- Cited by
- 122
- References
- 0
- FWCI
- 4.96
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.