CoChat

Reproducibility of ambulatory blood pressure monitoring in hemodialysis patients

Open access
Peixoto, Aldo J., Santos, Sérgio F.F., Mendes, Roger B., Crowley, Susan T., Maldonado, Rafael, Orias, Marcelo, Mansoor, George A., White, William B. · 2000 · American Journal of Kidney Diseases
Cited by 98

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Ambulatory blood pressure monitoring (ABPM) has been increasingly used in hemodialysis (HD) practice and research; however, no study has evaluated the reproducibility of ABPM in this population. To address this question, we performed 48-hour interdialytic ABPM on 21 HD patients (mean age, 53 +/- 16 years; 7 women) on two different occasions 68 +/- 34 days (range, 30 to 154 days) apart. To qualify for the protocol, patients had to be at the same dry weight and on the same vasoactive drug regimen at both monitoring periods. BP was analyzed according to three different methods: isolated pre-HD and post-HD values, average pre-HD and post-HD values for the five HD sessions surrounding each monitoring period, and 48-hour interdialytic ABPM. Reproducibility was determined by analysis of the SD of the differences (SDD) between the two monitoring periods and the coefficient of variation of each method of BP determination. Our results show better reproducibility of ABPM (SDD, 10.6/6.6 mm Hg; coefficient of variation, 7.5%/8.1%) compared with isolated pre-HD BP (SDD, 24.4/11.3 mm Hg; coefficient of variation, 16.7%/14.1%) or post-HD BP (SDD, 16.8/14.5 mm Hg; coefficient of variation, 11.7%/17.8%), and averaged pre-HD BP (SDD, 14.7/7.2 mm Hg; coefficient of variation, 10.1%/9.1%) or post-HD BP (SDD, 12.4/8.7 mm Hg; coefficient of variation, 8.9%/11.1%). The reproducibility of the decrease in BP during sleep was poor, with up to 43% of the subjects changing dipping category within or between interdialytic periods. We conclude that ABPM is the most accurate method to study BP in HD patients over time. However, variability is significant, and there is poor reproducibility of the nocturnal decline in BP.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1053/ajkd.2000.19100

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Peixoto, A. J., Santos, S. F. F., Mendes, R. B., Crowley, S. T., Maldonado, R., Orias, M., Mansoor, G. A., & White, W. B.
Venue
American Journal of Kidney Diseases
Publisher
Elsevier BV
Published
2000-11
Volume
36
Issue
5
Pages
983-990
ISSN
0272-6386 (ISSN-L)
OpenAlex
W1997571395
Cited by
98
References
2
FWCI
4.70
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.