The DOI matches its Crossref record.
Economics of Myocardial Perfusion Imaging in Europe—the EMPIRE study
Open accessAbstract
BACKGROUND: Physicians use myocardial perfusion imaging to a variable extent in patients presenting with possible coronary artery disease. There are few clinical data on the most cost-effective strategy although computer models predict that routine use of myocardial perfusion imaging is cost-effective. OBJECTIVES: To measure the cost-effectiveness of four diagnostic strategies in patients newly presenting with possible coronary artery disease, and to compare cost-effectiveness in centres that routinely use myocardial perfusion imaging with those that do not. METHODS: We have studied 396 patients presenting to eight hospitals for the diagnosis of coronary artery disease. The hospitals were regular users or non-users of myocardial perfusion imaging with one of each in four countries (France, Germany, Italy, United Kingdom). Information was gathered retrospectively on presentation, investigations, complications, and clinical management, and patients were followed-up for 2 years in order to assess outcome. Pre- and post-test probabilities of coronary artery disease were computed for diagnostic tests and each test was also assigned as diagnostic or part of management. Diagnostic strategies defined were: 1: Exercise electrocardiogram/coronary angiography, 2: exercise electrocardiogram/myocardial perfusion imaging/coronary angiography, 3: myocardial perfusion imaging/coronary angiography, 4: coronary angiography. Primary outcome measures were the cost and accuracy of diagnosis, the cost of subsequent management, and clinical outcome. Secondary measures included prognostic power, normal angiography rate, and rate of angiography not followed by revascularization. RESULTS: Mean diagnostic costs per patient were: strategy 1: 490 Pounds, 2: 409 Pounds, 3: 460 Pounds, 4: 1253 Pounds (P < 0.0001). Myocardial perfusion imaging users: 529 Pounds, non-users 667 Pounds (P = 0.006). Mean probability of the presence of coronary artery disease when the final clinical diagnosis was coronary artery disease present were, strategy 1: 0.85, 2: 0.82, 3: 0.97, 4: 1.0 (P < 0.0001), users 0.93, non-users 0.88 (P = 0.02), and when coronary artery disease was absent, 1: 0.26, 2: 0.22, 3: 0.16, 4: 0.0 (P < 0.0001), users 0.21, non-users 0.20 (P = ns). Total 2-year costs (coronary artery disease present/absent) were: strategy 1: 4453 Pounds/710 Pounds, 2: 3842 Pounds/478 Pounds, 3: 3768 Pounds/574 Pounds, 4: 5599 Pounds/1475 Pounds (P < 0.05/0.0001), users: 5563 Pounds/623 Pounds, non-users: 5428 Pounds/916 Pounds (P = ns/0.001). Prognostic power at diagnosis was higher (P < 0.0001) and normal coronary angiography rate lower (P = 0.07) in the scintigraphic centres and strategies. Numbers of soft and hard cardiac events over 2 years and final symptomatic status did not differ between strategy or centre. CONCLUSION: Investigative strategies using myocardial perfusion imaging are cheaper and equally effective when compared with strategies that do not use myocardial perfusion imaging, both for cost of diagnosis and for overall 2 year management costs. Two year patient outcome is the same.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fihn, S. D., Gardin, J. M., Abrams, J., Berra, K., Blankenship, J. C., Dallas, A. P., Douglas, P. S., Foody, J. M., Gerber, T. C., Hinderliter, A. L., et al. (2012) · Circulation · doi:10.1161/cir.0b013e3182776f83 · Cited by 2,410
Fihn, S. D., Gardin, J. M., Abrams, J., Berra, K., Blankenship, J. C., Dallas, A. P., Douglas, P. S., Foody, J. M., Gerber, T. C., Hinderliter, A. L., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.07.013 · Cited by 1,555
Fihn, S. D., Gardin, J. M., Abrams, J., Berra, K., Blankenship, J. C., Dallas, A. P., Douglas, P. S., Foody, J. M., Gerber, T. C., Hinderliter, A. L., et al. (2012) · Circulation · doi:10.1161/cir.0b013e318277d6a0 · Cited by 845
Underwood, S. R., Anagnostopoulos, C., Cerqueira, M., Ell, P. J., Flint, E. J., Harbinson, M., Kelion, A. D., Al-Mohammad, A., Prvulovich, E. M., Shaw, L. J., et al. (2004) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-003-1344-5 · Cited by 481
Self-citationMowatt, G., Cummins, E., Waugh, N., Walker, S., Cook, J., Jia, X., Hillis, G., & Fraser, C. (2008) · Health Technology Assessment · doi:10.3310/hta12170 · Cited by 261
Sabharwal, N. K., & Lahiri, A. (2003) · Heart · doi:10.1136/heart.89.11.1291 · Cited by 72
“The EMPIRE (economics of myocardial perfusion imaging in Europe) study 50 compared 396 patient records from eight hospitals in four European countries.”
Metadata
- Authors
- Underwood, S.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 1999-01
- Volume
- 20
- Issue
- 2
- Pages
- 157-166
- ISSN
- 0195-668X (ISSN-L)
- OpenAlex
- W2138032033
- Cited by
- 181
- References
- 0
- FWCI
- 8.20
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.