The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Left and Right Atrial Volume by Freehand Three-dimensional Echocardiography: In Vivo Validation Using Magnetic Resonance Imaging
Abstract
INTRODUCTION: Measurement of left and right atrial size is important for the management of arrhythmias, valvular and congenital heart disease. We have demonstrated that freehand three-dimensional (3D) echocardiography is more accurate and reproducible than two-dimensional (2D) echocardiography for measurement of left ventricular mass and volume. However, no prior study has validated the accuracy of freehand 3D for the determination of left or right atrial volume. METHODS: End-systolic (maximum) left and right atrial volumes were determined in 21 volunteer patients and normal subjects by one, two, and freehand 3D transthoracic echocardiography and compared to volumes obtained by gradient recalled magnetic resonance imaging. Three-dimensional echocardiographic determination of atrial volume was obtained using an acoustic spatial locator, a line-of-intersection display, and a surface reconstruction algorithm. Two-dimensional echocardiographic atrial volumes were obtained from apical biplane images of the left atrium and an apical single plane image of the right atrium using a summation of disks method. One-dimensional (ID) estimates of left atrial volume were determined by cubing the M-mode ID antero-posterior dimension obtained on the parasternal long axis view. RESULTS: An excellent correlation was Obtained between freedhand 3D echocardiography and magnetic resonce imaging (MRI) for the left atrium (r = 0.90, SEE=9.6 ml) and for the right atrium (r = 0.91, SEE = 8.8 ml) with a small bias (left atrium 5.25 ml, right atrium 12.06 ml) and narrow limits of agreement (left atrium 22.14 ml, right atrium 25.54 ml). Two-dimensional echocardiography correlated less well (left atrium r = 0.87, SEE = 10.23 ml, right atrium r = 0.79, SEE = 19.74 ml), and had a higher bias (left atrium 14.46 ml, right atrium 8.99 ml) and larger limits of agreement (left atrium 24.37 ml, right atrium 41.16 ml). One-dimensional estimates of left atrial volume correlated poorly with magnetic resonance determined left atrial volume (r = 0.80, SEE = 6.61 ml) and had unacceptably high bias (45.09 ml) and limits of agreement (35.52 ml). Interobserver variability was lowest for 3D echocardiography (left atrium 7.2 ml, 11%, right atrium 8.7 ml, 16%). CONCLUSIONS: Freehand 3D echocardiography using the line of intersection display for guidance of image positioning and a polyhedral surface reconstruction algorithm is a valid, accurate, reproducible method for determining left and right atrial volume in humans that is comparable to magnetic resonance imaging and is superior to current ID and 2D echocardiographic techniques.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Echocardiographic predictors of nonrheumatic atrial fibrillation. The Framingham Heart Study.
Vaziri, S. M., Larson, M. G., Benjamin, E. J., & Levy, D. (1994) · Circulation · doi:10.1161/01.cir.89.2.724 · Cited by 1,073
Cited by
Lang, R. M., Bierig, M., Devereux, R. B., Flachskampf, F. A., Foster, E., Pellikka, P. A., Picard, M. H., Roman, M. J., Seward, J., Shanewise, J. S., et al. (2005) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2005.10.005 · Cited by 11,318
Lopez, L., Colan, S. D., Frommelt, P. C., Ensing, G. J., Kendall, K., Younoszai, A. K., Lai, W. W., & Geva, T. (2010) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2010.03.019 · Cited by 1,553
3D Echocardiography: A Review of the Current Status and Future Directions
Hung, J., Lang, R., Flachskampf, F., Shernan, S. K., McCulloch, M. L., Adams, D. B., Thomas, J., Vannan, M., & Ryan, T. (2007) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2007.01.010 · Cited by 335
Leung, D. Y., Boyd, A., Ng, A. A., Chi, C., & Thomas, L. (2008) · American Heart Journal · doi:10.1016/j.ahj.2008.07.021 · Cited by 288
Maceira, A. M., Cosín-Sales, J., Roughton, M., Prasad, S. K., & Pennell, D. J. (2010) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-12-65 · Cited by 274
Metadata
- Authors
- KELLER, A., GOPAL, A., & KING, D.
- Venue
- European Journal of Echocardiography
- Publisher
- Oxford University Press (OUP)
- Published
- 2000-03
- Volume
- 1
- Issue
- 1
- Pages
- 55-65
- ISSN
- 1525-2167 (ISSN-L)
- OpenAlex
- W2148754242
- Cited by
- 196
- References
- 1
- FWCI
- 0.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.