CoChat

Imprecision of Urinary Iothalamate Clearance as a Gold-Standard Measure of GFR Decreases the Diagnostic Accuracy of Kidney Function Estimating Equations

Open access
Kwong, Yuen-Ting (Diana), Stevens, Lesley A., Selvin, Elizabeth, Zhang, Yaping (Lucy), Greene, Tom, Van Lente, Frederick, Levey, Andrew S., Coresh, Josef · 2010 · American Journal of Kidney Diseases
Cited by 130

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Background Evaluating the accuracy of estimated glomerular filtration rate (eGFR) derived from serum creatinine (SCr) and serum cystatin C (SCysC) equations requires gold standard measures of GFR. However, the influence of imprecise measured GFRs (mGFRs) on estimates of equation error is unknown. Study Design Diagnostic test study Setting & Participants 1995 participants from the Modification of Diet in Renal Disease (MDRD) Study and African American Study of Kidney Disease (AASK) with at least two baseline mGFRs from125I-iothalamate urinary clearances, one standardized Scr value, and one SCysC value. Index Tests eGFRs calculated from the 4-variable IDMS-traceable MDRD Study equation, the CKD-EPI SCysC equation, the CKD-EPI SCr-SCysC equation, and mGFRs collected from another pre-randomization visit Reference Tests A single reference mGFR, average of two, and average of three mGFRs; additional analysis limited to consistent mGFRs (difference fl 25% from the reference mGFR) Results We found that mGFRs had stable means but substantial variability across visits. Of all the mGFRs collected a mean of 62 days apart from the reference visit, 8.0% fell outside 30% of the single reference mGFR (1-P30). The estimation equations were less accurate as 12.1%, 17.1% and 8.3% of the eGFR from MDRD Study, CKD-EPI SCysC, and CKD-EPI SCr-SCysC equations fell outside 30% of the same gold standard (1-P30). However, improving the precision of the reference test from a single mGFR to the average of three consistent mGFRs reduced these error estimates (1-P30) to 8.0%, 12.5% and 3.9% respectively. Limitations Study population limited to those with CKD. Conclusions Imprecision in gold standard measures of GFR contribute to an appreciable proportion of the cases where estimated and measured GFR differs by more than 30%. Reducing and quantifying errors in gold standard measurements of GFR is critical to fully estimating the accuracy of GFR estimates.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1053/j.ajkd.2010.02.347

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 130

Metadata

Authors
Kwong, Y.-T. (., Stevens, L. A., Selvin, E., Zhang, Y. (., Greene, T., Van Lente, F., Levey, A. S., & Coresh, J.
Venue
American Journal of Kidney Diseases
Publisher
Elsevier BV
Published
2010-07
Volume
56
Issue
1
Pages
39-49
ISSN
0272-6386 (ISSN-L)
OpenAlex
W2128168657
Cited by
130
References
1
FWCI
12.14
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.