Dialysis Catheter–Related Bloodstream Infections: A Cluster-Randomized Trial of the ClearGuard HD Antimicrobial Barrier Cap

Open access
Hymes, Jeffrey L., Mooney, Ann, Van Zandt, Carly, Lynch, Laurie, Ziebol, Robert, Killion, Douglas · 2017 · American Journal of Kidney Diseases
Cited by 54

The DOI matches its Crossref record.

Abstract

BACKGROUND: The rate of bloodstream infections (BSIs) is disproportionately high in hemodialysis (HD) patients with central venous catheters (CVCs) versus those with permanent accesses, contributing to poorer outcomes, such as increased rates of death and hospitalizations. STUDY DESIGN: 12-month, prospective, cluster-randomized, multicenter, open-label trial. SETTING & PARTICIPANTS: 40 Fresenius Medical Care North America dialysis facilities were matched and paired by positive blood culture rate and number of patients with CVCs and then cluster-randomized with 20 in each study group. 2,470 patients participated in the study (1,245, intervention group; 1,225, control group), accruing approximately 350,000 CVC-days. INTERVENTION: Use of ClearGuard HD Antimicrobial Barrier Caps versus use of standard CVC caps; assigned at the facility level. OUTCOME: Primary end point was positive blood culture rate as an indicator of BSI rate. MEASUREMENTS: Positive blood cultures, hospital admissions for BSI, hospitalization-days for BSI, intravenous antibiotic starts, and CVC-days. RESULTS: Baseline positive blood culture rates were similar (P=0.8) between groups. Use of ClearGuard HD caps for 12 months was associated with a 56% lower BSI rate versus use of standard CVC caps (0.26 vs 0.59/1,000 CVC-days, respectively; P=0.01). When considering sustained use (defined as last 6 months of the study), the intervention versus the control was associated with a 69% lower BSI rate (0.22 vs 0.72/1,000 CVC-days, respectively; P=0.01), 43% fewer hospital admissions for BSI (0.28 vs 0.48/1,000 CVC-days, respectively; P=0.04), and 51% fewer hospitalization days for BSI (2.42 vs 4.94/1,000 CVC-days, respectively; P=0.04). No device-related adverse events were reported. LIMITATIONS: Study was open label; patients occasionally received HD at nonresearch facilities; patients did not receive the intervention when hospitalized. CONCLUSIONS: The findings show that use of ClearGuard HD Antimicrobial Barrier Caps, when compared with standard CVC caps, significantly lowers rates of catheter-related BSIs and hospital admissions for BSI in HD patients using CVCs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1053/j.ajkd.2016.09.014

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 54

Metadata

Authors
Hymes, J. L., Mooney, A., Van Zandt, C., Lynch, L., Ziebol, R., & Killion, D.
Venue
American Journal of Kidney Diseases
Publisher
Elsevier BV
Published
2017-02
Volume
69
Issue
2
Pages
220-227
ISSN
0272-6386 (ISSN-L)
OpenAlex
W2553137705
Cited by
54
References
0
FWCI
8.20
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Dialysis Catheter–Related Bloodstream Infections: A Cluster-Randomized Trial of the ClearGuard HD Antimicrobial Barrier Cap. https://app.cochat.ai/papers/10.1053/j.ajkd.2016.09.014
The paper
Hymes, J. L., Mooney, A., Van Zandt, C., Lynch, L., Ziebol, R., & Killion, D. (2017). Dialysis Catheter–Related Bloodstream Infections: A Cluster-Randomized Trial of the ClearGuard HD Antimicrobial Barrier Cap. American Journal of Kidney Diseases. https://doi.org/10.1053/j.ajkd.2016.09.014

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.