The DOI matches its Crossref record; 89 of the 89 references it cites were found in a registry or an index.
Recent Advances in Ultrasound Technology
Abstract
Technical improvements have made profound changes in diagnostic ultrasound imaging. Some of these changes, such as encoded pulses and receive focusing, occur in the background and are essentially nonadjustable. Others, including harmonics and compounding, are real-time options and are adjustable by the imager. New technologies that offer great promise for improved characterization of lesions include contrast ultrasound and elastography. This article will attempt to update the small animal imager on the clinical applications of these newer technologies.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Elastography: Ultrasonic estimation and imaging of the elastic properties of tissues
Ophir, J., Alam, S. K., Garra, B., Kallel, F., Konofagou, E., Krouskop, T., & Varghese, T. (1999) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/0954411991534933 · Cited by 784
Ultrasound contrast agents: A review
Goldberg, B. B., Liu, J., & Forsberg, F. (1994) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(94)90001-9 · Cited by 489
Coded excitation for diagnostic ultrasound: a system developer's perspective
Chiao, R. Y., & Hao, X. (2005) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2005.1406543 · Cited by 299
Coded excitation for diagnostic ultrasound: a system developer's perspective
Chiao, R. Y., & Hao, X. (2004) · IEEE Symposium on Ultrasonics, 2003 · doi:10.1109/ultsym.2003.1293440 · Cited by 270
Elastography in the Detection of Prostatic Cancer
Cochlin, D. L., Ganatra, R. H., & Griffiths, D. F. R. (2002) · Clinical Radiology · doi:10.1053/crad.2002.0989 · Cited by 253
Second harmonic ultrasonic blood perfusion measurement
Schrope, B., & Newhouse, V. L. (1993) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(93)90080-8 · Cited by 247
Tissue harmonic imaging: Why does it work?
Thomas, J. D., & Rubin, D. N. (1998) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(98)70055-0 · Cited by 242
Essentials Of Ultrasound Physics
Zagzebski, J. A. (1996) · Cited by 240
Thomas, A. E., Fischer, T., Frey, H., Ohlinger, R., Grunwald, S., Blohmer, J., Winzer, K. ‐., Weber, S. P., Kristiansen, G., Ebert, B. G., et al. (2006) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.2823 · Cited by 229
Contrast–agent detection and quantification
Phillips, P., & Gardner, E. A. (2004) · European Radiology Supplements · doi:10.1007/s10406-004-0075-4 · Cited by 203
Cited by
Hayashida, N., Imaizumi, M., Shimura, H., Okubo, N., Asari, Y., Nigawara, T., Midorikawa, S., Kotani, K., Nakaji, S., Otsuru, A., et al. (2013) · PLoS ONE · doi:10.1371/journal.pone.0083220 · Cited by 85
RetractedUltrasound for the Anesthesiologists: Present and Future
Terkawi, A. S., Karakitsos, D., Elbarbary, M. A., Blaivas, M., & Durieux, M. E. (2013) · The Scientific World JOURNAL · doi:10.1155/2013/683685 · Cited by 83
A review of the Fukushima nuclear reactor accident
Nagataki, S., & Takamura, N. (2014) · Current Opinion in Endocrinology Diabetes and Obesity · doi:10.1097/med.0000000000000098 · Cited by 50
Looney, P., Yin, Y., Collins, S. L., Nicolaides, K. H., Plasencia, W., Molloholli, M., Natsis, S., & Stevenson, G. N. (2021) · IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · doi:10.1109/tuffc.2021.3052143 · Cited by 40
Real-time ultrasound (RTU) imaging methods for quality control of meats
Silva, S. R., & Cadavez, V. (2012) · Elsevier eBooks · doi:10.1533/9780857095770.3.277 · Cited by 26
Nyland, T. G., Larson, M. M., & Mattoon, J. S. (2014) · Elsevier eBooks · doi:10.1016/b978-1-4160-4867-1.00009-x · Cited by 24
Comparison of Transabdominal and Transrectal Ultrasound for Sizing of the Prostate
Pate, W. R., Garg, N., Wang, L. B., Wason, S. E. L., & Barbosa, P. V. (2020) · Urology · doi:10.1016/j.urology.2020.04.054 · Cited by 21
Faluyi, O. B., Agbede, J. O., & Adebayo, I. A. (2015) · Journal of Veterinary Medicine and Animal Health · doi:10.5897/jvmah2014.0328 · Cited by 19
Elastography: Principles and considerations for clinical research in veterinary medicine cibele
Carvalho, F., Thassila, C. F. C., & Maria, C. C. (2015) · Journal of Veterinary Medicine and Animal Health · doi:10.5897/jvmah2014.0344 · Cited by 12
Fischetti, A. J. (2011) · Elsevier eBooks · doi:10.1016/b978-1-4160-6621-7.00035-x · Cited by 8
Contrast-enhanced ultrasonography (CEUS) in canine liver examination
Wdowiak, M., Rychlik, A., Nieradka, R., & Nowicki, M. P. (2010) · Polish Journal of Veterinary Sciences · doi:10.2478/v10181-010-0007-2 · Cited by 6
Drost, W. T. (2018) · Elsevier eBooks · doi:10.1016/b978-0-323-48247-9.00016-4 · Cited by 4
Efficacy of Ultrasound Shear Wave Elastography in the Diagnosis of Salivary Gland Tumors
Abba, M., Allon, I., Markovich-Roth, T., Abramson, A., & London, D. (2023) · Journal of Oral and Maxillofacial Surgery · doi:10.1016/j.joms.2023.03.001 · Cited by 4
Ultrasound as a diagnostic tool in the investigation of a pony with intestinal lymphoma
SHERLOCK, C. E., Dawson, L. J., & Mair, T. S. (2015) · Equine Veterinary Education · doi:10.1111/eve.12401 · Cited by 4
New Techniques in Pediatric Ultrasound
Dumitriu, D., Galloy, M., & Claudon, M. (2010) · Ultrasound Clinics · doi:10.1016/j.cult.2009.11.015 · Cited by 4
Larson, M. M., Mattoon, J. S., Lawrence, Y. A., & Sellon, R. K. (2020) · Elsevier eBooks · doi:10.1016/b978-0-323-53337-9.00018-6 · Cited by 3
BASES FÍSICAS DA FORMAÇÃO DA IMAGEM ULTRASSONOGRÁFICA
Peixoto, G. C. X., Lira, R. A., Alves, N. D., & Silva, A. R. (2010) · Acta Veterinaria Brno · doi:10.21708/avb.2010.4.1.1538 · Cited by 3
López, F. A. S., Betancour, M. A. M., & Salazar, E. C. (2013) · TECCIENCIA · doi:10.18180/tecciencia.2013.15.2 · Cited by 3
Tarbell, A. L., & Fischetti, A. J. (2020) · Elsevier eBooks · doi:10.1016/b978-0-323-48435-0.00038-1 · Cited by 2
Advanced Ultrasonography Imaging
Orhan, K., & Bayrakdar, İ. Ş. (2021) · Springer eBooks · doi:10.1007/978-3-030-62179-7_5 · Cited by 1
Ultrasound image guidance of cardiac interventions
Peters, T. M., Pace, D. F., Lang, P., Guiraudon, G. M., Jones, D. L., & Linte, C. A. (2011) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.879843
López, F. A. S., Betancour, M. A. M., & Salazar, E. C. (2013) · Dialnet (Universidad de la Rioja)
Cole, R., & Hespel, A. (2020) · doi:10.1002/9781118840931.ch3
Effects of amiodarone on cardiac performance in arrhythmic dogs
Boonpala, P. (2014) · NRCT Data Center · doi:10.14457/cu.the.2014.1475
Ultraschalldiagnostik der Leber
Klambauer, K., Čečatka, S., & Clevert, D. (2023) · Die Radiologie · doi:10.1007/s00117-023-01138-3
Heng, H. G., & Drost, W. T. (2025) · Elsevier eBooks · doi:10.1016/b978-0-323-93235-6.00003-1
Advances in Diagnostic and Therapeutic Ultrasonography
Mamoulakis, C., Tzortzis, V., Rioja, J., Pes, M. P. L., Gravas, S., Wijkstra, H., & de la Rosette, J. J. M. C. H. (2010) · Springer eBooks · doi:10.1007/978-1-84882-178-1_27
Metadata
- Authors
- O’Brien, R. T., & Holmes, S. P.
- Affiliations
- Kansas State University (US)
- Washington State University (US)
- Corresponding author
- O’Brien, Robert T.
- ORCID
- Holmes, Shannon P.
- Venue
- Clinical Techniques in Small Animal Practice
- Publisher
- Elsevier BV
- Published
- 2007-08
- Volume
- 22
- Issue
- 3
- Pages
- 93-103
- ISSN
- 1096-2867 (ISSN-L)
- OpenAlex
- W2128439942
- Cited by
- 26
- References
- 87
- Citations by year
- 2025: 1 · 2023: 2 · 2021: 2 · 2020: 4 · 2018: 1 · 2015: 3 · 2014: 2 · 2013: 4 · 2012: 1
- FWCI
- 1.00
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Locations
- Clinical Techniques in Small Animal Practice (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Ultrasound Imaging and Elastography
- Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Ultrasound in Clinical Applications
- Physical Sciences › Engineering › Biomedical Engineering › Photoacoustic and Ultrasonic Imaging
- Keywords
- diagnostic ultrasound imaging, harmonic imaging, compounding, contrast-enhanced ultrasound, elastography, lesion characterization, small animal imaging, veterinary ultrasound
- MeSH terms
- Animals, Animal Diseases, Diagnosis, Differential, Image Processing, Computer-Assisted, Signal Processing, Computer-Assisted, Transducers, Ultrasonography, Imaging, Three-Dimensional
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.