CoChat

Difference in Performance of Fecal Immunochemical Tests With the Same Hemoglobin Cutoff Concentration in a Nationwide Colorectal Cancer Screening Program

Open access
Chiang, Tsung-Hsien, Chuang, Shu-Lin, Chen, Sam Li-Sheng, Chiu, Han-Mo, Yen, Amy Ming-Fang, Chiu, Sherry Yueh-Hsia, Fann, Jean Ching-Yuan, Chou, Chu-Kuang, Lee, Yi-Chia, Wu, Ming-Shiang, Chen, Hsiu-Hsi · 2014 · Gastroenterology
Cited by 113

The DOI matches its Crossref record.

Abstract

BACKGROUND & AIMS: We investigated whether 2 quantitative fecal immunochemical tests (FITs) with the same cutoff concentration of fecal hemoglobin perform equivalently in identifying patients with colorectal cancer (CRC). METHODS: A total of 956,005 Taiwanese subjects, 50 to 69 years old, participated in a nationwide CRC screening program to compare results from 2 FITs; 78% were tested using the OC-Sensor (n = 747,076; Eiken Chemical Co, Tokyo, Japan) and 22% were tested using the HM-Jack (n = 208,929; Kyowa Medex Co Ltd, Tokyo, Japan), from 2004 through 2009. The cutoff concentration for a positive finding was 20 μg hemoglobin/g feces, based on a standardized reporting unit system. The tests were compared using short-term and long-term indicators of performance. RESULTS: The OC-Sensor test detected CRC in 0.21% of patients, with a positive predictive value of 6.8%. The HM-Jack test detected CRC in 0.17% of patients, with a positive predictive value of 5.2%. The rate of interval cancer rate was 30.7/100,000 person-years among subjects receiving the OC-Sensor test and 40.6/100,000 person-years among those receiving the HM-Jack test; there was significant difference in test sensitivity (80% vs 68%, P = .005) that was related to the detectability of proximal CRC. After adjusting for differences in city/county, age, sex, ambient temperature, and colonoscopy quality, significant differences were observed between the tests in the positive predictive value for cancer detection (adjusted relative risk = 1.29; 95% confidence interval, 1.14-1.46) and the rates of interval cancer (0.75; 95% confidence interval, 0.62-0.92). Although each test was estimated to reduce CRC mortality by approximately 10%, no significant difference in mortality was observed when the 2 groups were compared. CONCLUSIONS: Different brands of quantitative FITs, even with the same cutoff hemoglobin concentration, perform differently in mass screening. Population-level data should be gathered to verify the credibility of quantitative laboratory findings.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1053/j.gastro.2014.08.043

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Chiang, T.-H., Chuang, S.-L., Chen, S. L.-S., Chiu, H.-M., Yen, A. M.-F., Chiu, S. Y.-H., Fann, J. C.-Y., Chou, C.-K., Lee, Y.-C., Wu, M.-S., & Chen, H.-H.
Venue
Gastroenterology
Publisher
Elsevier BV
Published
2014-12
Volume
147
Issue
6
Pages
1317-1326
ISSN
0016-5085 (ISSN-L)
OpenAlex
W2106261190
Cited by
113
References
0
FWCI
6.46
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.