de Groof, Albert J., Struyvenberg, Maarten R., van der Putten, Joost, van der Sommen, Fons, Fockens, Kiki N., Curvers, Wouter L., Zinger, Sveta, Pouw, Roos E., Coron, Emmanuel, Baldaque-Silva, Francisco, Pech, Oliver, Weusten, Bas, Meining, Alexander, Neuhaus, Horst, Bisschops, Raf, Dent, John, Schoon, Erik J., de With, Peter H., Bergman, Jacques J. · 2020 · Gastroenterology

Abstract

BACKGROUND & AIMS We aimed to develop and validate a deep-learning computer-aided detection (CAD) system, suitable for use in real time in clinical practice, to improve endoscopic detection of early neoplasia in patients with Barrett's esophagus (BE). METHODS We developed a hybrid ResNet-UNet model CAD system using 5 independent endoscopy datasets. We performed pre-training using 494,364 labelled endoscopic images collected from all intestinal segments. Then, we used 1704 unique esophageal high-resolution images of rigorously confirmed early-stage neoplasia from patients with BE, and non-dysplastic BE, derived from 669 patients. System performance was assessed using datasets 4 and 5. Dataset 5 was also scored by 53 general endoscopists with a wide range of experience from 4 countries to benchmark CAD system performance. Coupled with histopathology findings, scoring of images that contained early-stage neoplasia in datasets 2-5 were delineated in detail for neoplasm position and extent by multiple experts whose evaluations served as the ground truth for segmentation. RESULTS The CAD system classified images as containing neoplasms or non-dysplastic BE with 89% accuracy, 90% sensitivity, and 88% specificity (dataset 4, 80 patients and images). In dataset 5 (80 patients and images) values for the CAD system vs those of the general endoscopists were 88% vs 73% accuracy, 93% vs 72% sensitivity, and 83% vs 74% specificity. The CAD system achieved higher accuracy than any of the individual 53 non-expert endoscopists, with comparable delineation performance. CAD delineations of the area of neoplasm overlapped with those from the BE experts in all detected neoplasia in datasets 4 and 5. The CAD system identified the optimal site for biopsy of detected neoplasia in 97% and 92% of cases (dataset 4 and 5 respectively). CONCLUSIONS We developed, validated, and benchmarked a deep-learning computer-aided system for primary detection of neoplasia in patients with BE. The system detected neoplasia with high accuracy and near-perfect delineation performance.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1053/j.gastro.2019.11.030

Cites

28 of 28 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 28 references

Cited by

See all 340

Metadata

Authors
de Groof, A. J., Struyvenberg, M. R., van der Putten, J., van der Sommen, F., Fockens, K. N., Curvers, W. L., Zinger, S., Pouw, R. E., Coron, E., Baldaque-Silva, F., Pech, O., Weusten, B., Meining, A., Neuhaus, H., Bisschops, R., Dent, J., Schoon, E. J., de With, P. H., & Bergman, J. J.
Venue
Gastroenterology
Publisher
Elsevier BV
Published
2020-03
Volume
158
Issue
4
Pages
915-929.e4
ISSN
0016-5085 (ISSN-L)
OpenAlex
W2989631244
Cited by
340
References
28
FWCI
20.15
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Deep-Learning System Detects Neoplasia in Patients With Barrett’s Esophagus With Higher Accuracy Than Endoscopists in a Multistep Training and Validation Study With Benchmarking. https://app.cochat.ai/papers/10.1053/j.gastro.2019.11.030
The paper
de Groof, A. J., Struyvenberg, M. R., van der Putten, J., van der Sommen, F., Fockens, K. N., Curvers, W. L., Zinger, S., Pouw, R. E., Coron, E., Baldaque-Silva, F., Pech, O., Weusten, B., Meining, A., Neuhaus, H., Bisschops, R., Dent, J., Schoon, E. J., de With, P. H., & Bergman, J. J. (2020). Deep-Learning System Detects Neoplasia in Patients With Barrett’s Esophagus With Higher Accuracy Than Endoscopists in a Multistep Training and Validation Study With Benchmarking. Gastroenterology. https://doi.org/10.1053/j.gastro.2019.11.030

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.