CoChat

Cardiac PET Perfusion Tracers: Current Status and Future Directions

Open access
Maddahi, Jamshid, Packard, René R.S. · 2014 · Seminars in Nuclear Medicine
Cited by 163

The DOI matches its Crossref record.

Abstract

Positron emission tomography (PET) myocardial perfusion imaging (MPI) is increasingly used for non-invasive detection and evaluation of coronary artery disease (CAD). However, the widespread use of PET MPI has been limited by shortcomings of the current PET perfusion tracers. Availability of these tracers is limited by need for an on-site (15O water and 13N ammonia) or nearby (13N ammonia) cyclotron or commitment to costly generators (82Rb). Due to short half-lives ranging from 76sec for 82Rb, to 2.1min for 15O water and 10min for 13N ammonia, their use in conjunction with treadmill exercise stress testing is either not possible (82Rb and 15O water) or is not practical (13N ammonia). Furthermore, the long positron range of 82Rb makes image resolution suboptimal and its low extraction limits its defect resolution. In recent years, development of an 18F labeled PET perfusion tracer has gathered considerable interest. The longer half-life of 18F (108 minutes) would make the tracer available as a unit dose from regional cyclotrons and allow use in conjunction with treadmill exercise testing. Furthermore, the short positron range of 18F would result in better image resolution. 18F flurpiridaz is by far the most thoroughly studied in animal models, and is the only F18-based PET MPI radiotracer currently undergoing clinical evaluation. Pre-clinical and clinical experience with 18F flurpiridaz demonstrated a high myocardial extraction fraction, high image and defect resolution, high myocardial uptake, slow myocardial clearance, and high myocardial-to-background contrast which was stable over time – important properties of an ideal PET MPI radiotracer. Pre-clinical data from other 18F labeled myocardial perfusion tracers are encouraging.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1053/j.semnuclmed.2014.06.011

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Maddahi, J., & Packard, R. R. S.
Venue
Seminars in Nuclear Medicine
Publisher
Elsevier BV
Published
2014-09
Volume
44
Issue
5
Pages
333-343
ISSN
0001-2998 (ISSN-L)
OpenAlex
W2154021966
Cited by
163
References
0
FWCI
8.42
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Cardiac PET Perfusion Tracers: Current Status and Future Directions. https://app.cochat.ai/papers/10.1053/j.semnuclmed.2014.06.011
The paper
Maddahi, J., & Packard, R. R. S. (2014). Cardiac PET Perfusion Tracers: Current Status and Future Directions. Seminars in Nuclear Medicine. https://doi.org/10.1053/j.semnuclmed.2014.06.011

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.