Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 188

The DOI matches its Crossref record.

Arthroscopic repair of full-thickness tears of the rotator cuff

Wilson, Franklin, Hinov, Viktor, Adams, Gayl·2002·Arthroscopy: The Journal of Arthroscopic & Related Surgery

Abstract

PURPOSE: This study was performed to evaluate 2 arthroscopic techniques for rotator cuff repair used by 1 surgeon for more than 12 years. The main objective of this study was to test the reliability of these arthroscopic repair techniques not only using clinical assessment during the follow-up, but through observation of the healing process of the tendons during the arthroscopic removal of the staples in our first group of patients. TYPE OF STUDY: This study was a before/after trial. METHODS: We present the results of arthroscopic repair of full-thickness rotator cuff tears in 100 patients. In group I, 35 patients had staple fixation, and in group II, 65 patients had side-to-side suture and anchor repair. Follow-up ranged from 2 to 14 years. All shoulders were evaluated using the UCLA rating scale. Shoulders repaired with staples (group I) were evaluated arthroscopically at staple removal. Arthroscopic subacromial decompression was performed in 26 of the 35 patients in group I and in 65 of the 65 patients in group II; 58 patients in group II had concomitant resection of distal clavicle. RESULTS: In group I, 22 patients (63%) had excellent results (UCLA scores, 34-35), 7 (20%) had good results (UCLA scores, 28-33), 4 (11%) had fair results (UCLA scores, 21-27), and 2 (6%) of the patients had poor results (UCLA scores, 0-20). In group II, 47 patients (72%) had excellent results (UCLA scores, 34-35), 12 (19%) had good results (UCLA scores, 28-33), 2 (3%) had fair results (UCLA scores, 21-27), and 4 (6%) of the patients had poor results (UCLA scores, 0-20). CONCLUSIONS: Patients with well-healed rotator cuff tendons had satisfactory postoperative results and better overall functional results. The arthroscopic techniques for rotator cuff repair achieve results comparable to the results of traditional open repair. However, these technically demanding arthroscopic procedures require advanced arthroscopic skills and have a steep learning curve.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1053/jars.2002.30443

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 188

Metadata

Authors
Wilson, F., Hinov, V., & Adams, G.
Venue
Arthroscopy: The Journal of Arthroscopic & Related Surgery
Publisher
Elsevier BV
Published
2002-02
Volume
18
Issue
2
Pages
136-144
ISSN
0749-8063 (ISSN-L)
OpenAlex
W2101597926
Cited by
188
References
0
FWCI
11.80
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Arthroscopic repair of full-thickness tears of the rotator cuff. https://app.cochat.ai/papers/10.1053/jars.2002.30443
The paper
Wilson, F., Hinov, V., & Adams, G. (2002). Arthroscopic repair of full-thickness tears of the rotator cuff. Arthroscopy: The Journal of Arthroscopic & Related Surgery. https://doi.org/10.1053/jars.2002.30443

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.