The DOI matches its Crossref record.
Sensitivity of MRI to proteoglycan depletion in cartilage: comparison of sodium and proton MRI
Open accessAbstract
OBJECTIVE: The purpose of this work was to evaluate the results from sodium and proton magnetic resonance imaging (MRI) in detecting small changes in proteoglycan (PG) content in bovine articular cartilage specimens. DESIGN: Articular cartilage from 15 specimens of bovine patellae were subjected to partial PG depletion with different concentrations of trypsin for 30 min. Sodium and proton MR images of the intact specimen were obtained on a 4T GE clinical MRI system. Two custom-built 7 cm-diameter solenoid coils tuned to proton and sodium frequencies were employed. Fast gradient echo and spin echo imaging sequences were used to determine sodium density, proton density and proton relaxation times (T(1)and T(2)) of the specimens. Spectrophotometric assay was performed after MRI to determine PG concentrations of the cartilage specimens. RESULTS: The sodium signal change correlated well with the observed PG loss (R(2)=0.85, P< 0.01) whereas the proton signal change was inconsistent (R(2)=0.10, P< 0.8). The change in proton T(1)and T(2)between the two regions did not correlate with PG loss (R(2)=0. 07 and R(2)=0.06, respectively). CONCLUSIONS: Results from these studies demonstrate that sodium MRI is both sensitive and specific in detecting small changes in PG concentration, whereas proton density and relaxation properties are not sensitive to small changes in PG content.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Animal models of osteoarthritis: classification, update, and measurement of outcomes
Kuyinu, E. L., Narayanan, G., Nair, L. S., & Laurencin, C. T. (2016) · Journal of Orthopaedic Surgery and Research · doi:10.1186/s13018-016-0346-5 · Cited by 583
Pros and cons of ultra-high-field MRI/MRS for human application
Ladd, M. E., Bachert, P., Meyerspeer, M., Moser, E., Nagel, A. M., Norris, D. G., Schmitter, S., Speck, O., Straub, S., & Zaiss, M. (2018) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2018.06.001 · Cited by 544
Crema, M. D., Roemer, F. W., Marra, M. D., Burstein, D., Gold, G. E., Eckstein, F., Baum, T., Mosher, T. J., Carrino, J. A., & Guermazi, A. (2011) · RadioGraphics · doi:10.1148/rg.311105084 · Cited by 448
Diagnosis of osteoarthritis: Imaging
Braun, H. J., & Gold, G. E. (2012) · Bone · doi:10.1016/j.bone.2011.11.019 · Cited by 402
Proteoglycan‐induced changes in T1ρ‐relaxation of articular cartilage at 4T
Akella, S. V. S., Reddy Regatte, R., Gougoutas, A. J., Borthakur, A., Shapiro, E. M., Kneeland, J. B., Leigh, J. S., & Reddy, R. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1208 · Cited by 381
Self-citation
Metadata
- Authors
- Borthakur, A., Shapiro, E. M., Beers, J., Kudchodkar, S., Kneeland, J. B., & Reddy, R.
- Venue
- Osteoarthritis and Cartilage
- Publisher
- Elsevier BV
- Published
- 2000-07
- Volume
- 8
- Issue
- 4
- Pages
- 288-293
- ISSN
- 1063-4584 (ISSN-L)
- OpenAlex
- W2081565098
- Cited by
- 203
- References
- 0
- FWCI
- 3.09
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sensitivity of MRI to proteoglycan depletion in cartilage: comparison of sodium and proton MRI. https://app.cochat.ai/papers/10.1053/joca.1999.0303
- The paper
- Borthakur, A., Shapiro, E. M., Beers, J., Kudchodkar, S., Kneeland, J. B., & Reddy, R. (2000). Sensitivity of MRI to proteoglycan depletion in cartilage: comparison of sodium and proton MRI. Osteoarthritis and Cartilage. https://doi.org/10.1053/joca.1999.0303
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.