Evaluation of the effects of an artificial intelligence system on endoscopy quality and preliminary testing of its performance in detecting early gastric cancer: a randomized controlled trial

Wu, Lianlian, He, Xinqi, Liu, Mei, Xie, Huaping, An, Ping, Zhang, Jun, Zhang, Heng, Ai, Yaowei, Tong, Qiaoyun, Guo, Mingwen, Huang, Manling, Ge, Cunjin, Yang, Zhi, Yuan, Jingping, Liu, Jun, Zhou, Wei, Jiang, Xiaoda, Huang, Xu, Mu, Ganggang, Wan, Xinyue, Li, Yanxia, Wang, Hongguang, Wang, Yonggui, Zhang, Hongfeng, Chen, Di, Gong, Dexin, Wang, Jing, Huang, Li, Li, Jia, Yao, Liwen, Zhu, Yijie, Yu, Honggang · 2021 · Endoscopy

Abstract

Background Esophagogastroduodenoscopy (EGD) is a prerequisite for detecting upper gastrointestinal lesions especially early gastric cancer (EGC). An artificial intelligence system has been shown to monitor blind spots during EGD. In this study, we updated the system (ENDOANGEL), verified its effectiveness in improving endoscopy quality, and pretested its performance in detecting EGC in a multicenter randomized controlled trial. Methods ENDOANGEL was developed using deep convolutional neural networks and deep reinforcement learning. Patients undergoing EGD in five hospitals were randomly assigned to the ENDOANGEL-assisted group or to a control group without use of ENDOANGEL. The primary outcome was the number of blind spots. Secondary outcomes included performance of ENDOANGEL in predicting EGC in a clinical setting. Results 1050 patients were randomized, and 498 and 504 patients in the ENDOANGEL and control groups, respectively, were analyzed. Compared with the control group, the ENDOANGEL group had fewer blind spots (mean 5.38 [standard deviation (SD) 4.32] vs. 9.82 [SD 4.98]; P < 0.001) and longer inspection time (5.40 [SD 3.82] vs. 4.38 [SD 3.91] minutes; P < 0.001). In the ENDOANGEL group, 196 gastric lesions with pathological results were identified. ENDOANGEL correctly predicted all three EGCs (one mucosal carcinoma and two high grade neoplasias) and two advanced gastric cancers, with a per-lesion accuracy of 84.7 %, sensitivity of 100 %, and specificity of 84.3 % for detecting gastric cancer. Conclusions In this multicenter study, ENDOANGEL was an effective and robust system to improve the quality of EGD and has the potential to detect EGC in real time.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1055/a-1350-5583

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 168

Metadata

Authors
Wu, L., He, X., Liu, M., Xie, H., An, P., Zhang, J., Zhang, H., Ai, Y., Tong, Q., Guo, M., Huang, M., Ge, C., Yang, Z., Yuan, J., Liu, J., Zhou, W., Jiang, X., Huang, X., Mu, G., Wan, X., Li, Y., Wang, H., Wang, Y., Zhang, H., Chen, D., Gong, D., Wang, J., Huang, L., Li, J., Yao, L., Zhu, Y., & Yu, H.
Venue
Endoscopy
Published
2021-01-11
Volume
53
Issue
12
Pages
1199-1207
ISSN
  • 0013-726X (ISSN-L)
  • 1438-8812
OpenAlex
W3183182400
Cited by
168
References
5
FWCI
9.26
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of the effects of an artificial intelligence system on endoscopy quality and preliminary testing of its performance in detecting early gastric cancer: a randomized controlled trial. https://app.cochat.ai/papers/10.1055/a-1350-5583
The paper
Wu, L., He, X., Liu, M., Xie, H., An, P., Zhang, J., Zhang, H., Ai, Y., Tong, Q., Guo, M., Huang, M., Ge, C., Yang, Z., Yuan, J., Liu, J., Zhou, W., Jiang, X., Huang, X., Mu, G., . . . Yu, H. (2021). Evaluation of the effects of an artificial intelligence system on endoscopy quality and preliminary testing of its performance in detecting early gastric cancer: a randomized controlled trial. Endoscopy. https://doi.org/10.1055/a-1350-5583

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.