The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Evaluation of the effects of an artificial intelligence system on endoscopy quality and preliminary testing of its performance in detecting early gastric cancer: a randomized controlled trial
Abstract
Background Esophagogastroduodenoscopy (EGD) is a prerequisite for detecting upper gastrointestinal lesions especially early gastric cancer (EGC). An artificial intelligence system has been shown to monitor blind spots during EGD. In this study, we updated the system (ENDOANGEL), verified its effectiveness in improving endoscopy quality, and pretested its performance in detecting EGC in a multicenter randomized controlled trial. Methods ENDOANGEL was developed using deep convolutional neural networks and deep reinforcement learning. Patients undergoing EGD in five hospitals were randomly assigned to the ENDOANGEL-assisted group or to a control group without use of ENDOANGEL. The primary outcome was the number of blind spots. Secondary outcomes included performance of ENDOANGEL in predicting EGC in a clinical setting. Results 1050 patients were randomized, and 498 and 504 patients in the ENDOANGEL and control groups, respectively, were analyzed. Compared with the control group, the ENDOANGEL group had fewer blind spots (mean 5.38 [standard deviation (SD) 4.32] vs. 9.82 [SD 4.98]; P < 0.001) and longer inspection time (5.40 [SD 3.82] vs. 4.38 [SD 3.91] minutes; P < 0.001). In the ENDOANGEL group, 196 gastric lesions with pathological results were identified. ENDOANGEL correctly predicted all three EGCs (one mucosal carcinoma and two high grade neoplasias) and two advanced gastric cancers, with a per-lesion accuracy of 84.7 %, sensitivity of 100 %, and specificity of 84.3 % for detecting gastric cancer. Conclusions In this multicenter study, ENDOANGEL was an effective and robust system to improve the quality of EGD and has the potential to detect EGC in real time.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A survey on deep learning in medical image analysis
Litjens, G., Kooi, T., Bejnordi, B. E., Setio, A. A. A., Ciompi, F., Ghafoorian, M., van der Laak, J. A. W. M., van Ginneken, B., & Sánchez, C. I. (2017) · Medical Image Analysis · doi:10.1016/j.media.2017.07.005 · Cited by 15,332
FuseNet: Incorporating Depth into Semantic Segmentation via Fusion-Based CNN Architecture
Hazirbas, C., Ma, L., Domokos, C., & Cremers, D. (2017) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-54181-5_14 · Cited by 902
Transfer Learning for Visual Categorization: A Survey
Shao, L., Zhu, F., & Li, X. (2015) · IEEE Transactions on Neural Networks and Learning Systems · doi:10.1109/tnnls.2014.2330900 · Cited by 895 · cited 1×
“Briefly, the VGG-16 CNN model was trained using transfer learning [17] with 12220 in vitro images, 25222 in vivo images, and 16760 unqualified images, which were filtered to retrieve only clear in vivo frames; the model achieved an accuracy of 97.6% in 3000 still images (model 1).”
InfluentialHirasawa, T., Aoyama, K., Tanimoto, T., Ishihara, S., Shichijo, S., Ozawa, T., Ohnishi, T., Fujishiro, M., Matsuo, K., Fujisaki, J., et al. (2018) · Gastric Cancer · doi:10.1007/s10120-018-0793-2 · Cited by 744
Jin, E. H., Lee, D., Bae, J. H., Kang, H. Y., Kwak, M.-S., Seo, J. Y., Yang, J. I., Yang, S. Y., Lim, S. H., Yim, J. Y., et al. (2020) · Gastroenterology · doi:10.1053/j.gastro.2020.02.036 · Cited by 140
Cited by
Randomized Clinical Trials of Machine Learning Interventions in Health Care: A Systematic Review
Plana, D., Shung, D. L., Grimshaw, A. A., Saraf, A., Sung, J. J. Y., & Kann, B. H. (2022) · JAMA Network Open · doi:10.1001/jamanetworkopen.2022.33946 · Cited by 236
Randomized Controlled Trials of Artificial Intelligence in Clinical Practice: Systematic Review
Lam, T. Y. T., Cheung, M. F. K., Munro, Y. L., Lim, K. M., Shung, D., & Sung, J. J. Y. (2022) · Journal of Medical Internet Research · doi:10.2196/37188 · Cited by 120
Martindale, A. P. L., Llewellyn, C. D., de Visser, R. O., Ng, B., Ngai, V., Kale, A. U., di Ruffano, L. F., Golub, R. M., Collins, G. S., Moher, D., et al. (2024) · Nature Communications · doi:10.1038/s41467-024-45355-3 · Cited by 58
Metadata
- Authors
- Wu, L., He, X., Liu, M., Xie, H., An, P., Zhang, J., Zhang, H., Ai, Y., Tong, Q., Guo, M., Huang, M., Ge, C., Yang, Z., Yuan, J., Liu, J., Zhou, W., Jiang, X., Huang, X., Mu, G., Wan, X., Li, Y., Wang, H., Wang, Y., Zhang, H., Chen, D., Gong, D., Wang, J., Huang, L., Li, J., Yao, L., Zhu, Y., & Yu, H.
- Venue
- Endoscopy
- Publisher
- Georg Thieme Verlag KG
- Published
- 2021-01-11
- Volume
- 53
- Issue
- 12
- Pages
- 1199-1207
- ISSN
- 0013-726X (ISSN-L)
- 1438-8812
- OpenAlex
- W3183182400
- Cited by
- 168
- References
- 5
- FWCI
- 9.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of the effects of an artificial intelligence system on endoscopy quality and preliminary testing of its performance in detecting early gastric cancer: a randomized controlled trial. https://app.cochat.ai/papers/10.1055/a-1350-5583
- The paper
- Wu, L., He, X., Liu, M., Xie, H., An, P., Zhang, J., Zhang, H., Ai, Y., Tong, Q., Guo, M., Huang, M., Ge, C., Yang, Z., Yuan, J., Liu, J., Zhou, W., Jiang, X., Huang, X., Mu, G., . . . Yu, H. (2021). Evaluation of the effects of an artificial intelligence system on endoscopy quality and preliminary testing of its performance in detecting early gastric cancer: a randomized controlled trial. Endoscopy. https://doi.org/10.1055/a-1350-5583
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.