Performance of a new integrated computer-assisted system (CADe/CADx) for detection and characterization of colorectal neoplasia
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Background Use of artificial intelligence may increase detection of colorectal neoplasia at colonoscopy by improving lesion recognition (CADe) and reduce pathology costs by improving optical diagnosis (CADx). Methods A multicenter library of ≥ 200 000 images from 1572 polyps was used to train a combined CADe/CADx system. System testing was performed on two independent image sets (CADe: 446 with polyps, 234 without; CADx: 267) from 234 polyps, which were also evaluated by six endoscopists (three experts, three non-experts). Results CADe showed sensitivity, specificity, and accuracy of 92.9 %, 90.6 %, and 91.7 %, respectively. Experts showed significantly higher accuracy and specificity, and similar sensitivity, while non-experts + CADe showed comparable sensitivity but lower specificity and accuracy than CADe and experts. CADx showed sensitivity, specificity, and accuracy of 85.0 %, 79.4 %, and 83.6 %, respectively. Experts showed comparable performance, whereas non-experts + CADx showed comparable accuracy but lower specificity than CADx and experts. Conclusions The high accuracy shown by CADe and CADx was similar to that of experts, supporting further evaluation in a clinical setting. When using CAD, non-experts achieved a similar performance to experts, with suboptimal specificity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zhao, S., Wang, S., Pan, P., Xia, T., Chang, X., Yang, X., Guo, L., Meng, Q., Yang, F., Qian, W., et al. (2019) · Gastroenterology · doi:10.1053/j.gastro.2019.01.260 · Cited by 660 · cited 1×
“A non-negligible rate of post-colonoscopy interval colorectal cancer has been related to the miss rate of colorectal neoplasia [3 – 5].”
BackgroundRex, D. K., Kahi, C., O'Brien, M., Levin, T. R., Pohl, H., Rastogi, A., Burgart, L., Imperiale, T., Ladabaum, U., Cohen, J., et al. (2011) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2011.01.023 · Cited by 629 · cited 1×
“By predicting histology in vivo, such pathology costs may be averted by the implementation of the “ leave-in-situ ” and “ resect and discard ” strategies [8,9].”
Background
Cited by
Rondonotti, E., Hassan, C., Tamanini, G., Antonelli, G., Andrisani, G., Leonetti, G., Paggi, S., Amato, A., Scardino, G., Di Paolo, D., et al. (2023) · Endoscopy · doi:10.1055/a-1852-0330 · Cited by 128
“Preliminary retrospective data in an artificial setting have shown high feasibility and accuracy levels of AI for optical diagnosis of colorectal polyps [7, 8], especially when focusing on diminutive rectosigmoid polyps (DRSPs) [9–12].”
BackgroundMethodSelf-citationNakashima, H., Kitazawa, N., Fukuyama, C., Kawachi, H., Kawahira, H., Momma, K., & Sakaki, N. (2023) · Digestion · doi:10.1159/000528085 · Cited by 49
Hassan, C., Sharma, P., Mori, Y., Bretthauer, M., Rex, D. K., Spadaccini, M., Selvaggio, C., Antonelli, G., Khalaf, K., Rizkala, T., et al. (2023) · Gastroenterology · doi:10.1053/j.gastro.2022.10.021 · Cited by 46
“Several CADx-systems for optical diagnosis of colorectal polyps are commercially available 6,8 .”
BackgroundMethodSelf-citationYuba, M., & Iwasaki, K. (2022) · Scientific Reports · doi:10.1038/s41598-022-21426-7 · Cited by 25
Metadata
- Authors
- Weigt, J., Repici, A., Antonelli, G., Afifi, A., Kliegis, L., Correale, L., Hassan, C., & Neumann, H.
- Venue
- Endoscopy
- Publisher
- Georg Thieme Verlag KG
- Published
- 2021-01-25
- Volume
- 54
- Issue
- 02
- Pages
- 180-184
- ISSN
- 0013-726X (ISSN-L)
- 1438-8812
- OpenAlex
- W3124075084
- Cited by
- 94
- References
- 2
- FWCI
- 5.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.