The influence of computer-aided polyp detection systems on reaction time for polyp detection and eye gaze
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Background Multiple computer-aided systems for polyp detection (CADe) have been introduced into clinical practice, with an unclear effect on examiner behavior. This study aimed to measure the influence of a CADe system on reaction time, mucosa misinterpretation, and changes in visual gaze pattern. Methods Participants with variable levels of colonoscopy experience viewed video sequences (n = 29) while eye movement was tracked. Using a crossover design, videos were presented in two assessments, with and without CADe support. Reaction time for polyp detection and eye-tracking metrics were evaluated. Results 21 participants performed 1218 experiments. CADe was significantly faster in detecting polyps compared with participants (median 1.16 seconds [99 %CI 0.40–3.43] vs. 2.97 seconds [99 %CI 2.53–3.77], respectively). However, the reaction time of participants when using CADe (median 2.90 seconds [99 %CI 2.55–3.38]) was similar to that without CADe. CADe increased misinterpretation of normal mucosa and reduced the eye travel distance. Conclusions Results confirm that CADe systems detect polyps faster than humans. However, use of CADe did not improve human reaction times. It increased misinterpretation of normal mucosa and decreased the eye travel distance. Possible consequences of these findings might be prolonged examination time and deskilling.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Adenoma detection rate and risk of colorectal cancer and death
Corley, D. A., Jensen, C. D., Marks, A. R., Zhao, W. K., Lee, J. K., Doubeni, C. A., Zauber, A. G., de Boer, J., Fireman, B. H., Schottinger, J. E., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1309086 · Cited by 2,270
Efficacy of real-time computer-aided detection of colorectal neoplasia in a randomized trial
Repici, A., Badalamenti, M., Maselli, R., Correale, L., Radaelli, F., Rondonotti, E., Ferrara, E., Spadaccini, M., Alkandari, A., Fugazza, A., et al. (2020) · Gastroenterology · doi:10.1053/j.gastro.2020.04.062 · Cited by 646
Hassan, C., Spadaccini, M., Iannone, A., Maselli, R., Jovani, M., Chandrasekar, V. T., Antonelli, G., Yu, H., Areia, M., Dinis-Ribeiro, M., et al. (2021) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2020.06.059 · Cited by 529
Hassan, C., Wallace, M. B., Sharma, P., Maselli, R., Craviotto, V., Spadaccini, M., & Repici, A. (2020) · Gut · doi:10.1136/gutjnl-2019-319914 · Cited by 189 · cited 2×
“27 seconds between colonoscopists and the CADe system [8].”
Optimizing the quality of colorectal cancer screening worldwide
Kaminski, M. F., Robertson, D. J., Senore, C., & Rex, D. K. (2020) · Gastroenterology · doi:10.1053/j.gastro.2019.11.026 · Cited by 171 · cited 1×
“The main indicator for the quality of screening colonoscopy is the adenoma detection rate (ADR) [1,2].”
Computer-aided detection-assisted colonoscopy: classification and relevance of false positives
Hassan, C., Badalamenti, M., Maselli, R., Correale, L., Iannone, A., Radaelli, F., Rondonotti, E., Ferrara, E., Spadaccini, M., Alkandari, A., et al. (2020) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2020.06.021 · Cited by 81
Cited by
Budzyń, K., Romańczyk, M., Kitala, D., Kołodziej, P., Bugajski, M., Adami, H. O., Blom, J., Buszkiewicz, M., Halvorsen, N., Hassan, C., et al. (2025) · The Lancet Gastroenterology & Hepatology · doi:10.1016/s2468-1253(25)00133-5 · Cited by 313
“23 In a similar study carried out in AI for breast cancer detection for mammography, physicians’ detection capability significantly decreased when AI support was expected.”
Rams, hounds and white boxes: investigating human–AI collaboration protocols in medical diagnosis
Cabitza, F., Campagner, A., Ronzio, L., Cameli, M., Mandoli, G. E., Pastore, M. C., Sconfienza, L. M., Folgado, D., Barandas, M., & Gamboa, H. (2023) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2023.102506 · Cited by 117
Artificial Intelligence-assisted colonoscopy and colorectal cancer screening: Where are we going?
Spadaccini, M., Troya, J., Khalaf, K., Facciorusso, A., Maselli, R., Hann, A., & Repici, A. (2024) · Digestive and Liver Disease · doi:10.1016/j.dld.2024.01.203 · Cited by 20
Self-citationBerzin, T. M., & Glissen Brown, J. (2023) · American Journal of Gastroenterology · doi:10.14309/ajg.0000000000002286 · Cited by 10
Metadata
- Authors
- Troya, J., Fitting, D., Brand, M., Sudarevic, B., Kather, J. N., Meining, A., & Hann, A.
- Venue
- Endoscopy
- Publisher
- Georg Thieme Verlag KG
- Published
- 2022-02-14
- Volume
- 54
- Issue
- 10
- Pages
- 1009-1014
- ISSN
- 0013-726X (ISSN-L)
- 1438-8812
- OpenAlex
- W4213128956
- Cited by
- 70
- References
- 6
- FWCI
- 5.08
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The influence of computer-aided polyp detection systems on reaction time for polyp detection and eye gaze. https://app.cochat.ai/papers/10.1055/a-1770-7353
- The paper
- Troya, J., Fitting, D., Brand, M., Sudarevic, B., Kather, J. N., Meining, A., & Hann, A. (2022). The influence of computer-aided polyp detection systems on reaction time for polyp detection and eye gaze. Endoscopy. https://doi.org/10.1055/a-1770-7353
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.