Real-Time Sonoelastography: Findings in Patients with Symptomatic Achilles Tendons and Comparison to Healthy Volunteers
Abstract
PURPOSE: Real-time sonoelastography (SE), a newly introduced ultrasound technique, has already shown conclusive results in breast, prostate, and thyroid tumor diagnostics. This study investigated the performance of SE for the differentiation of Achilles tendon alterations of tendinopathy compared to clinical examination and conventional ultrasound (US). MATERIALS AND METHODS: Achilles tendons in 25 consecutive patients with chronic Achilles tendinopathy and 25 healthy volunteers were examined clinically by US and by SE. RESULTS: In the healthy volunteers, SE showed the tendon to be hard (93 %), while distinct softening was found in 57 % of the patients. SE showed more frequent involvement of the distal (64 %) and middle third (80 %) than the proximal third (28 %) of the Achilles tendon. Using SE a mean sensitivity of 94 %, specificity of 99 %, and accuracy of 97 % were found when clinical examination was used as the reference standard. The correlation to US was 0.89. Mild softening was found in 7 % of the healthy volunteers and in 11 % of the patients. CONCLUSION: Our results emphasize that only distinct softening of Achilles tendons is comparable to clinical examination and US findings. However, mild softening might be explained by very early changes in tissue elasticity in the case of Achilles tendinopathy, which should be assessed in follow-up studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cosgrove, D., Piscaglia, F., Bamber, J., Bojunga, J., Correas, J.-M., Gilja, O., Klauser, A., Sporea, I., Calliada, F., Cantisani, V., et al. (2013) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/s-0033-1335375 · Cited by 955
Self-citationUltrasound elastography for musculoskeletal applications
Drakonaki, E. E., Allen, G. M., & Wilson, D. J. (2012) · The British Journal of Radiology · doi:10.1259/bjr/93042867 · Cited by 385
Săftoiu, A., Gilja, O. H., Sidhu, P. S., Dietrich, C. F., Cantisani, V., Amy, D., Bachmann-Nielsen, M., Bob, F., Bojunga, J., Brock, M., et al. (2019) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/a-0838-9937 · Cited by 320
Self-citationMartin, R. L., Chimenti, R., Cuddeford, T., Houck, J., Matheson, J. W., McDonough, C. M., Paulseth, S., Wukich, D. K., & Carcia, C. R. (2018) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.2018.0302 · Cited by 255
Tendinopathy: Is Imaging Telling Us the Entire Story?
Docking, S. I., Ooi, C. C., & Connell, D. (2015) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.2015.5880 · Cited by 214
Metadata
- Authors
- De Zordo, T., Chhem, R., Smekal, V., Feuchtner, G., Reindl, M., Fink, C., Faschingbauer, R., Jaschke, W., & Klauser, A.
- Venue
- Ultraschall in der Medizin - European Journal of Ultrasound
- Publisher
- Georg Thieme Verlag KG
- Published
- 2009-11-27
- Volume
- 31
- Issue
- 04
- Pages
- 394-400
- ISSN
- 0172-4614 (ISSN-L)
- 1438-8782
- OpenAlex
- W2067355397
- Cited by
- 211
- References
- 0
- FWCI
- 4.93
- Type
- journal article
- Language
- de
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Real-Time Sonoelastography: Findings in Patients with Symptomatic Achilles Tendons and Comparison to Healthy Volunteers. https://app.cochat.ai/papers/10.1055/s-0028-1109809
- The paper
- De Zordo, T., Chhem, R., Smekal, V., Feuchtner, G., Reindl, M., Fink, C., Faschingbauer, R., Jaschke, W., & Klauser, A. (2009). Real-Time Sonoelastography: Findings in Patients with Symptomatic Achilles Tendons and Comparison to Healthy Volunteers. Ultraschall in der Medizin - European Journal of Ultrasound. https://doi.org/10.1055/s-0028-1109809
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.