Magnifying endoscopy for diagnosing and delineating early gastric cancer
The DOI matches its Crossref record.
Abstract
We describe the basic principles and clinical usefulness of modern magnifying endoscopy techniques, using white-light imaging or narrow-band imaging, for precise diagnosis of small flat gastric cancers. Regarding technology, first, the resolution provided by the endoscope is important in order to consistently visualize the precise morphology of microvascular architecture, and second, the use of a distal attachment (soft hood or cap) is essential in order to maintain a constant distance between the tip of the scope and the mucosal surface. Regarding methodology, a systematic but simple classification system based on microvascular pattern and microsurface pattern (the "VS classification") is proposed. The technique based on the principles described here can be applied not only in routine endoscopic examination but also in the detailed preoperative assessment of the lateral extent of early gastric cancer, before endoscopic mucosal resection (EMR) or endoscopic submucosal dissection (ESD).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Magnifying endoscopy simple diagnostic algorithm for early gastric cancer (MESDA‐G)
Muto, M., Yao, K., Kaise, M., Kato, M., Uedo, N., Yagi, K., & Tajiri, H. (2016) · Digestive Endoscopy · doi:10.1111/den.12638 · Cited by 278
Self-citationLi, L., Chen, Y., Shen, Z., Zhang, X., Sang, J., Ding, Y., Yang, X., Li, J., Chen, M., Jin, C., et al. (2020) · Gastric Cancer · doi:10.1007/s10120-019-00992-2 · Cited by 216
“1) [6, 7, 10].”
Dinis-Ribeiro, M., Libânio, D., Uchima, H., Spaander, M. C. W., Bornschein, J., Matysiak-Budnik, T., Tziatzios, G., Santos-Antunes, J., Areia, M., Chapelle, N., et al. (2025) · Endoscopy · doi:10.1055/a-2529-5025 · Cited by 193
Kanesaka, T., Lee, T.-C., Uedo, N., Lin, K.-P., Chen, H.-Z., Lee, J.-Y., Wang, H.-P., & Chang, H.-T. (2018) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2017.11.029 · Cited by 173
Ang, T. L., Pittayanon, R., Lau, J. Y. W., Rerknimitr, R., Ho, S. H., Singh, R., Kwek, A. B. E., Ang, D. S. W., Chiu, P. W. Y., Luk, S., et al. (2015) · European Journal of Gastroenterology & Hepatology · doi:10.1097/meg.0000000000000478 · Cited by 90
Rodríguez-Carrasco, M., Esposito, G., Libânio, D., Pimentel-Nunes, P., & Dinis-Ribeiro, M. (2020) · Endoscopy · doi:10.1055/a-1205-0570 · Cited by 69
Kanemitsu, T., Yao, K., Nagahama, T., Imamura, K., Fujiwara, S., Ueki, T., Chuman, K., Tanabe, H., Atsuko, O., Iwashita, A., et al. (2017) · Endoscopy · doi:10.1055/s-0043-103409 · Cited by 64
“Furthermore, to maintain a fixed focal distance between the mucosal surface and the endoscope tip during magnifying endoscopic examinations at maximum magnification, a black soft hood (MAJ1989 for the GIF-Q240Z, MAJ1990 for the GIF-H260Z; Olympus) was mounted to the distal end of the endoscope [16].”
BackgroundSelf-citation
Metadata
- Authors
- Yao, K., Anagnostopoulos, G., & Ragunath, K.
- Venue
- Endoscopy
- Publisher
- Georg Thieme Verlag KG
- Published
- 2009-05
- Volume
- 41
- Issue
- 05
- Pages
- 462-467
- ISSN
- 0013-726X (ISSN-L)
- 1438-8812
- OpenAlex
- W2054004806
- Cited by
- 460
- References
- 0
- FWCI
- 11.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.