CoChat

Effective ”short” double-balloon enteroscope for diagnostic and therapeutic ERCP in patients with altered gastrointestinal anatomy: a large case series

Shimatani, M., Matsushita, M., Takaoka, M., Koyabu, M., Ikeura, T., Kato, K., Fukui, T., Uchida, K., Okazaki, K. · 2009 · Endoscopy
Cited by 228

The DOI matches its Crossref record.

Abstract

BACKGROUND AND STUDY AIMS: Although endoscopic retrograde cholangiopancreatography (ERCP) is technically challenging in patients with altered gastrointestinal anatomy, a double-balloon enteroscope (DBE) permits examinations of a much longer segment of the small bowel than does a standard endoscope, and may be used to perform ERCP in such patients. Since only limited accessories are available for a conventional DBE, we performed ERCP with a "short" DBE, which has a 2.8-mm working channel and a 152-cm working length and for which conventional accessories are available, in patients with altered gastrointestinal anatomy, and evaluated this alternative technique. PATIENTS AND METHODS: In 68 patients with a Roux-en-Y total gastrectomy (n = 36), Billroth II gastrectomy (n = 17), or pancreatoduodenectomy (n = 15), ERCP (103 procedures) was performed with a "short" DBE. RESULTS: Deep insertion was successful in 100/103 procedures (97 %). Cholangiogram was successfully obtained in 98/100 procedures (98 %). Treatment was accomplished in all 98 procedures in which a cholangiogram was obtained (100 %). Therapeutic interventions including stone extraction (n = 47), nasobiliary drainage (n = 38), stent placement (n = 36), sphincterotomy (n = 31), choledochojejunostomy dilation (n = 29), tumor biopsy (n = 10), and naso-pancreatic duct drainage (n = 1) were performed successfully. Complications occurred in 5/103 procedures (5 %), all in patients with Roux-en-Y reconstruction. CONCLUSIONS: Despite the relatively high rate of complications seen in patients with Roux-en-Y reconstruction, ERCP with a "short" DBE is effective in patients who have undergone bowel reconstruction.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1055/s-0029-1215108

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 228

Metadata

Authors
Shimatani, M., Matsushita, M., Takaoka, M., Koyabu, M., Ikeura, T., Kato, K., Fukui, T., Uchida, K., & Okazaki, K.
Venue
Endoscopy
Published
2009-09-11
Volume
41
Issue
10
Pages
849-854
ISSN
  • 0013-726X (ISSN-L)
  • 1438-8812
OpenAlex
W2000098366
Cited by
228
References
0
FWCI
7.62
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effective ”short” double-balloon enteroscope for diagnostic and therapeutic ERCP in patients with altered gastrointestinal anatomy: a large case series. https://app.cochat.ai/papers/10.1055/s-0029-1215108
The paper
Shimatani, M., Matsushita, M., Takaoka, M., Koyabu, M., Ikeura, T., Kato, K., Fukui, T., Uchida, K., & Okazaki, K. (2009). Effective ”short” double-balloon enteroscope for diagnostic and therapeutic ERCP in patients with altered gastrointestinal anatomy: a large case series. Endoscopy. https://doi.org/10.1055/s-0029-1215108

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.