CoChat

Review of endoscopic devices for weight reduction: old and new balloons and implantable prostheses

Tsesmeli, N., Coumaros, D. · 2009 · Endoscopy

The DOI matches its Crossref record.

Abstract

The worldwide epidemic of obesity is forecast to worsen with a concomitant increase in the burden of co-morbid conditions. Bariatric surgery has some disadvantages, and intragastric balloons (IGBs) represent a generally safe, reversible and less invasive approach to weight reduction, based on occupying gastric space to enhance the sensation of satiety. A literature review found that the majority of the published data on IGBs relates to the Bioenterics intragastric balloon (BIB). The evidence for the efficacy of the BIB as a primary means of weight loss is still unconvincing, but it appears to have value in subgroups of patients, for example to improve quality of life, ameliorate co-morbidities, or provide a bridge to surgery. Regarding other IGBs, even if there are promising weight loss results, more evidence and development is generally needed: it is difficult to evaluate the Heliosphere Bag because of the limited clinical experience; the Adjustable Totally Implantable Intragastric Prosthesis (ATIIP)-Endogast may have problems associated with the percutaneous endoscopic gastrotomy (PEG)-type insertion method; the Semistationary Antral Balloon (SAB) may require technical improvements; and the Silimed Gastric Balloon (SGB) warrants further investigation. Another implantable device, the endoscopic duodenal-jejunal sleeve is based on a different concept, that of mimicking bariatric surgery; it effectively bypasses the duodenum and jejunum, and shows promising results. Other endoscopically implantable devices, such as the "Butterfly" and tubular membranes are at an experimental stage.

Overview

Integrity signals

Registry

Crossref · 10.1055/s-0029-1215269

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Still being checked.

Cited by

See all 50

Metadata

Authors
Tsesmeli, N., & Coumaros, D.
Affiliations
Hôpitaux Universitaires de Strasbourg (FR)
Venue
Endoscopy
Published
2009-11-06
Volume
41
Issue
12
Pages
1082-1089
ISSN
  • 0013-726X (ISSN-L)
  • 1438-8812
OpenAlex
W2006112630
Cited by
49
References
0
Citations by year
2025: 1 · 2024: 2 · 2023: 5 · 2022: 3 · 2021: 2 · 2019: 4 · 2018: 3 · 2017: 1 · 2016: 1 · 2015: 1 · 2014: 4 · 2013: 3 · 2012: 7
FWCI
6.42
Type
journal article
Language
en
Open access
closed
Locations
  • Endoscopy (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Surgery › Bariatric Surgery and Outcomes
  • Health Sciences › Medicine › Surgery › Minimally Invasive Surgical Techniques
  • Health Sciences › Medicine › Pharmacology (medical) › Pharmacology and Obesity Treatment
Keywords
intragastric balloon, obesity, weight loss, endoscopic instruments, satiety, bariatric surgery alternatives, obesity-related comorbidities
MeSH terms
Humans, Obesity, Morbid, Weight Loss, Gastric Balloon, Endoscopy, Gastrointestinal, Prostheses and Implants, Endoscopes, Gastrointestinal, Bariatric Surgery

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Review of endoscopic devices for weight reduction: old and new balloons and implantable prostheses. https://app.cochat.ai/papers/10.1055/s-0029-1215269
The paper
Tsesmeli, N., & Coumaros, D. (2009). Review of endoscopic devices for weight reduction: old and new balloons and implantable prostheses. Endoscopy. https://doi.org/10.1055/s-0029-1215269

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.