The DOI matches its Crossref record.
High definition colonoscopy combined with i -Scan is superior in the detection of colorectal neoplasias compared with standard video colonoscopy: a prospective randomized controlled trial
Abstract
INTRODUCTION: Colonoscopy is the accepted gold standard for the detection of colorectal cancer. The aim of the current study was to prospectively compare high definition plus (HD+) colonoscopy with I-Scan functionality (electronic staining) vs. standard video colonoscopy. The primary endpoint was the detection of patients having colon cancer or at least one adenoma. METHODS: A total of 220 patients due to undergo screening colonoscopy, postpolypectomy surveillance or with a positive occult blood test were randomized in a 1 : 1 ratio to undergo HD+ colonoscopy in conjunction with I-Scan surface enhancement (90i series, Pentax, Tokyo, Japan) or standard video colonoscopy (EC-3870FZK, Pentax). Detected colorectal lesions were judged according to type, location, and size. Lesions were characterized in the HD+ group by using further I-Scan functionality (p- and v-modes) to analyze pattern and vessel architecture. Histology was predicted and biopsies or resections were performed on all identified lesions. RESULTS: HD+ colonoscopy with I-Scan functionality detected significantly more patients with colorectal neoplasia (38 %) compared with standard resolution endoscopy (13 %) (200 patients finally analyzed; 100 per arm). Significantly more neoplastic (adenomatous and cancerous) lesions and more flat adenomas could be detected using high definition endoscopy with surface enhancement. Final histology could be predicted with high accuracy (98.6 %) within the HD+ group. CONCLUSIONS: HD+ colonoscopy with I-Scan is superior to standard video colonoscopy in detecting patients with colorectal neoplasia based on this prospective, randomized, controlled trial.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bernal, J., Tajkbaksh, N., Sanchez, F. J., Matuszewski, B. J., Chen, H., Yu, L., Angermann, Q., Romain, O., Rustad, B., Balasingham, I., et al. (2017) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2664042 · Cited by 437
Kamiński, M., Hassan, C., Bisschops, R., Pohl, J., Pellisé, M., Dekker, E., Ignjatovic-Wilson, A., Hoffman, A., Longcroft-Wheaton, G., Heresbach, D., et al. (2014) · Endoscopy · doi:10.1055/s-0034-1365348 · Cited by 433
Self-citationAbu Dayyeh, B. K., Thosani, N., Konda, V., Wallace, M. B., Rex, D. K., Chauhan, S. S., Hwang, J. H., Komanduri, S., Manfredi, M., Maple, J. T., et al. (2015) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2014.12.022 · Cited by 389
Metadata
- Authors
- Hoffman, A., Sar, F., Goetz, M., Tresch, A., Mudter, J., Biesterfeld, S., Galle, P., Neurath, M., & Kiesslich, R.
- Venue
- Endoscopy
- Publisher
- Georg Thieme Verlag KG
- Published
- 2010-08-27
- Volume
- 42
- Issue
- 10
- Pages
- 827-833
- ISSN
- 0013-726X (ISSN-L)
- 1438-8812
- OpenAlex
- W2029327969
- Cited by
- 162
- References
- 0
- FWCI
- 7.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High definition colonoscopy combined with i -Scan is superior in the detection of colorectal neoplasias compared with standard video colonoscopy: a prospective randomized controlled trial. https://app.cochat.ai/papers/10.1055/s-0030-1255713
- The paper
- Hoffman, A., Sar, F., Goetz, M., Tresch, A., Mudter, J., Biesterfeld, S., Galle, P., Neurath, M., & Kiesslich, R. (2010). High definition colonoscopy combined with i -Scan is superior in the detection of colorectal neoplasias compared with standard video colonoscopy: a prospective randomized controlled trial. Endoscopy. https://doi.org/10.1055/s-0030-1255713
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.