CoChat

Endoscopic submucosal dissection in a European setting. A multi-institutional report of a technique in development

Farhat, S., Chaussade, S., Ponchon, T., Coumaros, D., Charachon, A., Barrioz, T., Koch, S., Houcke, P., Cellier, C., Heresbach, D., Lepilliez, V., Napoleon, B., Bauret, P., Coron, E., Le Rhun, M., Bichard, P., Vaillant, E., Calazel, A., Bensoussan, E., Bellon, S., Mangialavori, L., Robin, F., Prat, F. · 2011 · Endoscopy
Cited by 161

The DOI matches its Crossref record.

Abstract

BACKGROUND AND STUDY AIMS: Endoscopic submucosal dissection (ESD) is a technique for "en bloc" resection of superficial tumors of the gastrointestinal tract. In France, experience with this technique is still limited. We wanted to assess the development of ESD in France, with special attention to short term outcomes. PATIENTS AND METHODS: Members of the Société Française d'Endoscopie Digestive (SFED) who declared performing ESD reported their cases prospectively on a voluntary basis. Demographic, clinical, and technical data, and the results of immediate complications were collected. Case reports were completed prospectively by each investigator before pooled analysis. RESULTS: A total of 188 consecutive case reports were collected from 16 centers. The median case mix per center was 6 patients (range 1-43). The lesion sites treated by ESD were the stomach (n = 75), esophagus (n = 27), duodenum (n = 1), cecum (n = 2), right colon (n = 3), transverse colon (n = 5), sigmoid (n = 3), and rectum (n = 72). The median size of the lesions was 26 mm (range 2-150 mm). En bloc resection was achieved in 77.1% of cases, with complete R0 resection in 72.9%. Histopathology results showed high grade dysplasia or superficial cancer in 71.2%. The median duration of ESD was 105 minutes (range 20-450 minutes). The short term morbidity was 29.2% including 34 cases of perforation (18.1%), and 21 hemorrhages (11.2%) during the 24 hours following ESD, 89% of which were managed conservatively or endoscopically. CONCLUSION: In this early experience, the feasibility of ESD appeared to be good but R0 resection and complication rates did not match those reported by Japanese authors and must be improved by an extended practice.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1055/s-0030-1256413

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 161

Metadata

Authors
Farhat, S., Chaussade, S., Ponchon, T., Coumaros, D., Charachon, A., Barrioz, T., Koch, S., Houcke, P., Cellier, C., Heresbach, D., Lepilliez, V., Napoleon, B., Bauret, P., Coron, E., Le Rhun, M., Bichard, P., Vaillant, E., Calazel, A., Bensoussan, E., Bellon, S., Mangialavori, L., Robin, F., & Prat, F.
Venue
Endoscopy
Published
2011-05-27
Volume
43
Issue
08
Pages
664-670
ISSN
  • 0013-726X (ISSN-L)
  • 1438-8812
OpenAlex
W2065359718
Cited by
161
References
0
FWCI
14.10
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Endoscopic submucosal dissection in a European setting. A multi-institutional report of a technique in development. https://app.cochat.ai/papers/10.1055/s-0030-1256413
The paper
Farhat, S., Chaussade, S., Ponchon, T., Coumaros, D., Charachon, A., Barrioz, T., Koch, S., Houcke, P., Cellier, C., Heresbach, D., Lepilliez, V., Napoleon, B., Bauret, P., Coron, E., Le Rhun, M., Bichard, P., Vaillant, E., Calazel, A., Bensoussan, E., . . . Prat, F. (2011). Endoscopic submucosal dissection in a European setting. A multi-institutional report of a technique in development. Endoscopy. https://doi.org/10.1055/s-0030-1256413

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.