Validity and Reliability of the Wattbike Cycle Ergometer
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The purpose of this study was to assess the validity and reliability of the Wattbike cycle ergometer against the SRM Powermeter using a dynamic calibration rig (CALRIG) and trained and untrained human participants. Using the CALRIG power outputs of 50-1 250 W were assessed at cadences of 70 and 90 rev x min(-1). Validity and reliability data were also obtained from 3 repeated trials in both trained and untrained populations. 4 work rates were used during each trial ranging from 50-300 W. CALRIG data demonstrated significant differences (P<0.05) between SRM and Wattbike across the work rates at both cadences. Significant differences existed in recorded power outputs from the SRM and Wattbike during steady state trials (power outputs 50-300 W) in both human populations (156±72 W vs. 153±64 W for SRM and Wattbike respectively; P<0.05). The reliability (CV) of the Wattbike in the untrained population was 6.7% (95%CI 4.8-13.2%) compared to 2.2% with the SRM (95%CI 1.5-4.1%). In the trained population the Wattbike CV was 2.6% (95%CI 1.8-5.1%) compared to 1.1% with the SRM (95%CI 0.7-2.0%). These results suggest that when compared to the SRM, the Wattbike has acceptable accuracy. Reliability data suggest coaches and cyclists may need to use some caution when using the Wattbike at low power outputs in a test-retest setting.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Measures of Reliability in Sports Medicine and Science
Hopkins, W. G. (2000) · Sports Medicine · doi:10.2165/00007256-200030010-00001 · Cited by 4,635
Design and analysis of research on sport performance enhancement
HOPKINS, W. G., HAWLEY, J. A., & BURKE, L. M. (1999) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199903000-00018 · Cited by 708
Paton, C. D., & Hopkins, W. G. (2001) · Sports Medicine · doi:10.2165/00007256-200131070-00004 · Cited by 178
Cited by
McSwiney, F. T., Wardrop, B., Hyde, P. N., Lafountain, R. A., Volek, J. S., & Doyle, L. (2018) · Metabolism · doi:10.1016/j.metabol.2017.10.010 · Cited by 172
Muscle Oxygen Changes following Sprint Interval Cycling Training in Elite Field Hockey Players
Jones, B., Hamilton, D. K., & Cooper, C. E. (2015) · PLOS ONE · doi:10.1371/journal.pone.0120338 · Cited by 68
Hermassi, S., Schwesig, R., Aloui, G., Shephard, R. J., & Chelly, M. S. (2019) · Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000003068 · Cited by 36
Metadata
- Authors
- Hopker, J., Myers, S., Jobson, S. A., Bruce, W., & Passfield, L.
- Venue
- International Journal of Sports Medicine
- Publisher
- Georg Thieme Verlag KG
- Published
- 2010-07-27
- Volume
- 31
- Issue
- 10
- Pages
- 731-736
- ISSN
- 0172-4622 (ISSN-L)
- 1439-3964
- OpenAlex
- W2114642290
- Cited by
- 94
- References
- 4
- FWCI
- 1.73
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Validity and Reliability of the Wattbike Cycle Ergometer. https://app.cochat.ai/papers/10.1055/s-0030-1261968
- The paper
- Hopker, J., Myers, S., Jobson, S. A., Bruce, W., & Passfield, L. (2010). Validity and Reliability of the Wattbike Cycle Ergometer. International Journal of Sports Medicine. https://doi.org/10.1055/s-0030-1261968
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.