The DOI matches its Crossref record.
Safety of cold polypectomy for < 10 mm polyps at colonoscopy: a prospective multicenter study
Abstract
BACKGROUND: Cold polypectomy techniques (without electrocautery) by means of biopsy forceps or snare are widely adopted for the removal of subcentimetric polyps. However, few data are available on the safety of this approach. The aim of this study was to assess the safety of cold polypectomy for subcentimetric polyps, as well as the rate of advanced neoplasia in these lesions. PATIENTS AND METHODS: In a prospective multicenter trial, consecutive patients with at least one < 10-mm polyp at colonoscopy were prospectively included. All of the < 10-mm polyps detected within the study period were removed by cold polypectomy. The rates of immediate or delayed bleeding and other complications were assessed at 7 and 30 days after cold polypectomy by telephone calls. The rate of advanced histology was also assessed. Predictive variables of postpolypectomy bleeding or advanced neoplasia were identified by multivariate analysis. RESULTS: A total of 1015 < 10-mm polyps in 823 patients (15.5 % on antiplatelet agents) were removed. Of these, 822 (81 %) were ≤ 5 mm and 193 (19 %) were 6 - 9 mm. Immediate postpolypectomy bleeding occurred in 18 patients, corresponding to a per-patient and per-polyp bleeding rate of 2.2 % (95 % confidence interval [CI] 1.2 % - 3.2 %) and 1.8 % (95 %CI 1 % - 2.6 %), respectively. Therapy with antiplatelet agents (odds ratio [OR] 4; 95 %CI 1.5 - 10.6) and larger polyp size (OR 2; 95 %CI 1.1 - 6.9) were independent predictors of bleeding. Bleeding was successfully treated by endoscopic hemostasis in all cases and required no further medical intervention. Advanced neoplasia prevalence in polyps ≤ 5 mm was as high as 8.7 %. CONCLUSIONS: The results from this study showed the high safety of a cold polypectomy approach for subcentimetric polyps. This was due to the low rate of postpolypectomy bleeding and to the high efficacy of endoscopic hemostasis in its treatment. The high rate of advanced neoplasia in polyps ≤ 5 mm should prompt some caution on the management of these lesions following detection at computed tomography colonography or colon capsule endoscopy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Kamiński, M., Hassan, C., Bisschops, R., Pohl, J., Pellisé, M., Dekker, E., Ignjatovic-Wilson, A., Hoffman, A., Longcroft-Wheaton, G., Heresbach, D., et al. (2014) · Endoscopy · doi:10.1055/s-0034-1365348 · Cited by 433
Self-citationVeitch, A. M., Vanbiervliet, G., Gershlick, A. H., Boustiere, C., Baglin, T. P., Smith, L.-A., Radaelli, F., Knight, E., Gralnek, I. M., Hassan, C., et al. (2016) · Gut · doi:10.1136/gutjnl-2015-311110 · Cited by 296
Self-citationColonoscopy screening and surveillance guidelines
Saito, Y., Oka, S., Kawamura, T., Shimoda, R., Sekiguchi, M., Tamai, N., Hotta, K., Matsuda, T., Misawa, M., Tanaka, S., et al. (2021) · Digestive Endoscopy · doi:10.1111/den.13972 · Cited by 170
Metadata
- Authors
- Repici, A., Hassan, C., Vitetta, E., Ferrara, E., Manes, G., Gullotti, G., Princiotta, A., Dulbecco, P., Gaffuri, N., Bettoni, E., Pagano, N., Rando, G., Strangio, G., Carlino, A., Romeo, F., de Paula Pessoa Ferreira, D., Zullo, A., Ridola, L., & Malesci, A.
- Venue
- Endoscopy
- Publisher
- Georg Thieme Verlag KG
- Published
- 2011-11-28
- Volume
- 44
- Issue
- 01
- Pages
- 27-31
- ISSN
- 0013-726X (ISSN-L)
- 1438-8812
- OpenAlex
- W2520786713
- Cited by
- 241
- References
- 0
- FWCI
- 3.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Safety of cold polypectomy for < 10 mm polyps at colonoscopy: a prospective multicenter study. https://app.cochat.ai/papers/10.1055/s-0031-1291387
- The paper
- Repici, A., Hassan, C., Vitetta, E., Ferrara, E., Manes, G., Gullotti, G., Princiotta, A., Dulbecco, P., Gaffuri, N., Bettoni, E., Pagano, N., Rando, G., Strangio, G., Carlino, A., Romeo, F., de Paula Pessoa Ferreira, D., Zullo, A., Ridola, L., & Malesci, A. (2012). Safety of cold polypectomy for < 10 mm polyps at colonoscopy: a prospective multicenter study. Endoscopy. https://doi.org/10.1055/s-0031-1291387
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.