The DOI matches its Crossref record.
An EFSUMB Introduction into Dynamic Contrast-Enhanced Ultrasound (DCE-US) for Quantification of Tumour Perfusion
Abstract
Dynamic Contrast Enhanced Ultrasound (DCE-US) is an imaging technique that utilizes microbubble contrast agents in diagnostic ultrasound. The EFSUMB guidelines published in 2004, updated in 2008 and 2011 focused on the use of DCE-US, including essential technical requirements, training, investigational procedures and steps, guidance on image interpretation, established and recommended clinical indications and safety considerations. However the quantification of images acquired with ultrasound contrast agents (UCAs) is not discussed in the guidelines. The purpose of this EFSUMB document is to provide some recommendations and descriptions of the quantification of ultrasound images, technical requirements for analysis of time-intensity curves (TICs), methodology for data analysis, and interpretation of the results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ultrafast ultrasound localization microscopy for deep super-resolution vascular imaging
Errico, C., Pierre, J., Pezet, S., Desailly, Y., Lenkei, Z., Couture, O., & Tanter, M. (2015) · Nature · doi:10.1038/nature16066 · Cited by 1,349
Imaging biomarker roadmap for cancer studies
O'Connor, J. P. B., Aboagye, E. O., Adams, J. E., Aerts, H. J. W. L., Barrington, S. F., Beer, A. J., Boellaard, R., Bohndiek, S. E., Brady, M., Brown, G., et al. (2017) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2016.162 · Cited by 1,091
Self-citationSidhu, P., Cantisani, V., Dietrich, C., Gilja, O., Saftoiu, A., Bartels, E., Bertolotto, M., Calliada, F., Clevert, D.-A., Cosgrove, D., et al. (2018) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/a-0586-1107 · Cited by 1,086
Self-citationClaudon, M., Dietrich, C. F., Choi, B. I., Cosgrove, D. O., Kudo, M., Nolsøe, C. P., Piscaglia, F., Wilson, S. R., Barr, R. G., Chammas, M. C., et al. (2013) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2012.09.002 · Cited by 971
Self-citationClaudon, M., Dietrich, C., Choi, B., Cosgrove, D., Kudo, M., Nolsøe, C., Piscaglia, F., Wilson, S., Barr, R., Chammas, M., et al. (2012) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/s-0032-1325499 · Cited by 550
Self-citation
Metadata
- Authors
- Dietrich, C., Averkiou, M., Correas, J.-M., Lassau, N., Leen, E., & Piscaglia, F.
- Venue
- Ultraschall in der Medizin - European Journal of Ultrasound
- Publisher
- Georg Thieme Verlag KG
- Published
- 2012-07-27
- Volume
- 33
- Issue
- 04
- Pages
- 344-351
- ISSN
- 0172-4614 (ISSN-L)
- 1438-8782
- OpenAlex
- W2094785364
- Cited by
- 361
- References
- 0
- FWCI
- 11.34
- Type
- journal article
- Language
- de
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An EFSUMB Introduction into Dynamic Contrast-Enhanced Ultrasound (DCE-US) for Quantification of Tumour Perfusion. https://app.cochat.ai/papers/10.1055/s-0032-1313026
- The paper
- Dietrich, C., Averkiou, M., Correas, J.-M., Lassau, N., Leen, E., & Piscaglia, F. (2012). An EFSUMB Introduction into Dynamic Contrast-Enhanced Ultrasound (DCE-US) for Quantification of Tumour Perfusion. Ultraschall in der Medizin - European Journal of Ultrasound. https://doi.org/10.1055/s-0032-1313026
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.