Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 42Hernia repair and managementSurgical Sutures and AdhesivesStoma care and complications

The DOI matches its Crossref record; the references it cites are not checked yet.

Properties of Meshes used in Hernia Repair: A Comprehensive Review of Synthetic and Biologic Meshes

Ibrahim, Ahmed, Vargas, Christina, Colakoglu, Salih, Nguyen, John, Lin, Samuel, Lee, Bernard·2014·Journal of Reconstructive Microsurgery

Abstract

BACKGROUND: Data on the mechanical properties of the adult human abdominal wall have been difficult to obtain rendering manufacture of the ideal mesh for ventral hernia repair a challenge. An ideal mesh would need to exhibit greater biomechanical strength and elasticity than that of the abdominal wall. The aim of this study is to quantitatively compare the biomechanical properties of the most commonly used synthetic and biologic meshes in ventral hernia repair and presents a comprehensive literature review. METHODS: A narrative review of the literature was performed using the PubMed database spanning articles from 1982 to 2012 including a review of company Web sites to identify all available information relating to the biomechanical properties of various synthetic and biologic meshes used in ventral hernia repair. RESULTS: There exist differences in the mechanical properties and the chemical nature of different meshes. In general, most synthetic materials have greater stiffness and elasticity than what is required for abdominal wall reconstruction; however, each exhibits unique properties that may be beneficial for clinical use. On the contrary, biologic meshes are more elastic but less stiff and with a lower tensile strength than their synthetic counterparts. CONCLUSIONS: The current standard of practice for the treatment of ventral hernias is the use of permanent synthetic mesh material. Recently, biologic meshes have become more frequently used. Most meshes exhibit biomechanical properties over the known abdominal wall thresholds. Augmenting strength requires increasing amounts of material contributing to more stiffness and foreign body reaction, which is not necessarily an advantage.

Overview

Integrity signals

Registry

Crossref · 10.1055/s-0034-1376886

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

The citation lists are queued

They are fetched later and appear here then.

Cited by 42

Metadata

Authors
Ibrahim, A., Vargas, C., Colakoglu, S., Nguyen, J., Lin, S., & Lee, B.
Affiliations
  • Beth Israel Deaconess Medical Center (US)
  • Department of Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts
Corresponding author
Lee, Bernard
Venue
Journal of Reconstructive Microsurgery
Published
2014-09-05
Volume
31
Issue
02
Pages
083-094
ISSN
  • 0743-684X (ISSN-L)
  • 1098-8947
OpenAlex
W2334398443
Cited by
42
References
0
Citations by year
2026: 4 · 2025: 5 · 2024: 3 · 2023: 6 · 2022: 1 · 2021: 2 · 2020: 2 · 2019: 7 · 2018: 5 · 2017: 2 · 2016: 3 · 2015: 2
FWCI
2.31
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Reconstructive Microsurgery (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Surgery › Hernia repair and management
  • Health Sciences › Medicine › Surgery › Surgical Sutures and Adhesives
  • Health Sciences › Medicine › Surgery › Stoma care and complications
Keywords
ventral hernia repair, hernia mesh, synthetic mesh, biological mesh, abdominal wall biomechanics, mesh stiffness, tensile strength, abdominal wall reconstruction, foreign body reaction
MeSH terms
Biocompatible Materials, Biomechanical Phenomena, Hernia, Ventral, Humans, Materials Testing, Surface Properties, Surgical Mesh, Tensile Strength

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Properties of Meshes used in Hernia Repair: A Comprehensive Review of Synthetic and Biologic Meshes. https://app.cochat.ai/papers/10.1055/s-0034-1376886
The paper
Ibrahim, A., Vargas, C., Colakoglu, S., Nguyen, J., Lin, S., & Lee, B. (2014). Properties of Meshes used in Hernia Repair: A Comprehensive Review of Synthetic and Biologic Meshes. Journal of Reconstructive Microsurgery. https://doi.org/10.1055/s-0034-1376886

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.