The DOI matches its Crossref record.
Complete compression ultrasonography of the leg veins as a single test for the diagnosis of deep vein thrombosis: A prospective clinical outcome study
Abstract
Summary: Noninvasive diagnosis of deep vein thrombosis (DVT) is based on ultrasound examination of the leg veins, usually restricted to only compression of the proximal veins (CUS). Patients with negative CUS findings require a second examination or a combination with other tests, which impairs clinical efficiency. In this prospective outcome study, 1646 consecutive patients with clinically suspected DVT were examined once by a standardized protocol of complete compression ultrasound comprising all proximal and distal veins (CCUS) as the only diagnostic test. The examination was equivocal in 15 patients (1% technical failure rate). Another 366 patients (22%) were tested positive for proximal DVT, distal DVT, muscle vein thrombosis, or phlebitis. Of 1265 patients in whom CCUS findings were negative, 242 met exclusion criteria for follow-up (age <18, life expectancy <3 months, other reasons for anticoagulation, postthrombotic lesions of the leg veins, or lack of informed consent). During the 3 months of follow-up, three of 1023 patients with negative CCUS findings experienced a symptomatic venous thromboembolic event (0.3% [95% CI 0.1%-0.8%]). We conclude that the CCUS protocol has a low technical failure rate and is safe with respect to excluding DVT, thereby reducing the diagnostic workup of patients with suspected DVT to a single ultrasound examination.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
10-year follow-up of intensive glucose control in type 2 diabetes
Holman, R. R., Paul, S. K., Bethel, M. A., Matthews, D. R., & Neil, H. A. W. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0806470 · Cited by 7,751
Deep vein thrombosis and pulmonary embolism
Di Nisio, M., van Es, N., & Büller, H. R. (2016) · The Lancet · doi:10.1016/s0140-6736(16)30514-1 · Cited by 994
Kakkos, S. K., Gohel, M., Baekgaard, N., Bauersachs, R., Bellmunt-Montoya, S., Black, S. A., ten Cate-Hoek, A. J., Elalamy, I., Enzmann, F. K., Geroulakos, G., et al. (2021) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/j.ejvs.2020.09.023 · Cited by 743
Bates, S. M., Jaeschke, R., Stevens, S. M., Goodacre, S., Wells, P. S., Stevenson, M. D., Kearon, C., Schunemann, H. J., Crowther, M., Pauker, S. G., et al. (2012) · Chest · doi:10.1378/chest.11-2299 · Cited by 686
Goodacre, S., Sampson, F., Thomas, S., van Beek, E., & Sutton, A. (2005) · BMC Medical Imaging · doi:10.1186/1471-2342-5-6 · Cited by 376
Metadata
- Authors
- Schwarz, T., Halbritter, K., Beyer, J., Siegert, G., Oettler, W., Schmidt, B., Schroeder, H., & Schellong, S.
- Venue
- Thrombosis and Haemostasis
- Publisher
- Georg Thieme Verlag KG
- Published
- 2003
- Volume
- 89
- Issue
- 02
- Pages
- 228-234
- ISSN
- 0340-6245 (ISSN-L)
- 2567-689X
- OpenAlex
- W1851078690
- Cited by
- 217
- References
- 0
- FWCI
- 8.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Complete compression ultrasonography of the leg veins as a single test for the diagnosis of deep vein thrombosis: A prospective clinical outcome study. https://app.cochat.ai/papers/10.1055/s-0037-1613436
- The paper
- Schwarz, T., Halbritter, K., Beyer, J., Siegert, G., Oettler, W., Schmidt, B., Schroeder, H., & Schellong, S. (2003). Complete compression ultrasonography of the leg veins as a single test for the diagnosis of deep vein thrombosis: A prospective clinical outcome study. Thrombosis and Haemostasis. https://doi.org/10.1055/s-0037-1613436
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.