The DOI matches its Crossref record.
First Workshop for Detection of Heparin-induced Antibodies: Validation of the Heparin-induced Platelet-activation Test (HIPA) in Comparison with a PF4/Heparin ELISA
Abstract
Summary: Background. No data exist regarding the inter-laboratory reproducibility of the heparin-induced-platelet-activation (HIPA) test, the most widely used functional assay in Germany for the detection of heparin-induced thrombocytopenia (HIT) antibodies. Methods. Nine laboratories used an identical protocol to test eight different sera with the HIPA test. Five laboratories also tested the sera with a platelet factor 4 (PF4)/heparin-complex ELISA. Cross-reactivity with danaparoid-sodium was assessed using 0.2 aFXa units instead of heparin in the HIPA test. Results. Two of nine laboratories had no discrepant HIPA test results. Four laboratories differed in one sample, one reported two discrepant results, and two laboratories reported more than two discrepant results. Cross-reactivity with danaparoid-sodium test results differed among laboratories. PF4/heparin ELISA results were identical in all five laboratories. Conclusion. The HIPA test requires strict quality control measures. Using both a sensitive functional assay (HIPA test) and a PF4/heparin ELISA will allow detection of antibodies directed to antigens other than PF4/heparin complexes as well as detection of IgM and IgA antibodies with PF4/heparin specificity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Thrombotic thrombocytopenia after ChAdOx1 nCov-19 vaccination
Greinacher, A., Thiele, T., Warkentin, T. E., Weisser, K., Kyrle, P. A., & Eichinger, S. (2021) · New England Journal of Medicine · doi:10.1056/nejmoa2104840 · Cited by 2,259
Self-citationHirsh, J., Warkentin, T. E., Shaughnessy, S. G., Anand, S. S., Halperin, J. L., Raschke, R., Granger, C., Ohman, E. M., & Dalen, J. E. (2001) · Chest · doi:10.1378/chest.119.1_suppl.64s · Cited by 1,580
Heparin and Low-Molecular-Weight Heparin
Hirsh, J., Warkentin, T. E., Raschke, R., Granger, C., Ohman, E. M., & Dalen, J. E. (1998) · Chest · doi:10.1378/chest.114.5_supplement.489s · Cited by 1,031
Hirsh, J., Anand, S. S., Halperin, J. L., & Fuster, V. (2001) · Circulation · doi:10.1161/01.cir.103.24.2994 · Cited by 565
Heparin‐induced thrombocytopenia: pathogenesis and management
Warkentin, T. E. (2003) · British Journal of Haematology · doi:10.1046/j.1365-2141.2003.04334.x · Cited by 547
Metadata
- Authors
- Eichler, P., Budde, U., Haas, S., Kroll, H., Loreth, R. M., Meyer, O., Pachmann, U., Pötzsch, B., Schabel, A., Albrecht, D., & Greinacher, A.
- Venue
- Thrombosis and Haemostasis
- Publisher
- Georg Thieme Verlag KG
- Published
- 1999
- Volume
- 81
- Issue
- 04
- Pages
- 625-629
- ISSN
- 0340-6245 (ISSN-L)
- 2567-689X
- OpenAlex
- W1902526913
- Cited by
- 161
- References
- 0
- FWCI
- 7.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: First Workshop for Detection of Heparin-induced Antibodies: Validation of the Heparin-induced Platelet-activation Test (HIPA) in Comparison with a PF4/Heparin ELISA. https://app.cochat.ai/papers/10.1055/s-0037-1614536
- The paper
- Eichler, P., Budde, U., Haas, S., Kroll, H., Loreth, R. M., Meyer, O., Pachmann, U., Pötzsch, B., Schabel, A., Albrecht, D., & Greinacher, A. (1999). First Workshop for Detection of Heparin-induced Antibodies: Validation of the Heparin-induced Platelet-activation Test (HIPA) in Comparison with a PF4/Heparin ELISA. Thrombosis and Haemostasis. https://doi.org/10.1055/s-0037-1614536
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.