CoChat

The Sensitivity and Specificity of Commercial Reagents for the Detection of Lupus Anticoagulant Show Marked Differences in Performance between Photo-optical and Mechanical Coagulometers

Mackie, I. J., Purdy, G., Machin, S. J., Lawrie, A. S. · 1999 · Thrombosis and Haemostasis
Cited by 76

The DOI matches its Crossref record.

Abstract

Summary: This study was undertaken to appraise the application of those reagents most widely used in the UK for the detection and confirmation of lupus anticoagulant (LA) on an Amelung KC4A and a Sysmex CA-6000™ coagulometer. Five sets of dilute Russell’s viper venom time (DRVVT) reagents were assessed as well as the Textarin®-PL/ Ecarin ratio. Each DRVVT method comprised both LA detection and confirmation reagents provided by the same manufacturer. Samples were obtained from 20 normal healthy subjects, 10 LA-positive patients, 10 patients receiving oral anticoagulant therapy (OAT) who had previously been documented as LA-positive, a further 10 LA-negative patients receiving OAT and 10 LA-negative patients receiving unfractionated heparin therapy. The sensitivity and specificity of the reagents exhibited considerable variation not only between reagents, but also when the same reagent was used on the two analysers. Sensitivity ranged from 62 to 97% (all reagents both analysers), specificity went as low as 23% (Gradipore reagent on the CA-6000™) and as high as 100% (American Diagnostica Inc on both KC4A and CA-6000™). On the KC4A instrument, Unicorn Diagnostics’ lupus anticoagulant kit offered the best compromise of sensitivity and specificity (sensitivity 83% and specificity 81%). On the CA-6000™ the reagents supplied by American Diagnostica Inc exhibited optimal performance (sensitivity 90% and specificity 100%). The results indicate a need to optimise test reagents for specific analyser types, a procedure which can only be undertaken with preparations such as the proposed NIBSC reference plasmas for the detection of lupus anticoagulant.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1055/s-0037-1614567

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 76

Metadata

Authors
Mackie, I. J., Purdy, G., Machin, S. J., & Lawrie, A. S.
Venue
Thrombosis and Haemostasis
Published
1999
Volume
81
Issue
05
Pages
758-762
ISSN
  • 0340-6245 (ISSN-L)
  • 2567-689X
OpenAlex
W2228414425
Cited by
76
References
0
FWCI
4.38
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Sensitivity and Specificity of Commercial Reagents for the Detection of Lupus Anticoagulant Show Marked Differences in Performance between Photo-optical and Mechanical Coagulometers. https://app.cochat.ai/papers/10.1055/s-0037-1614567
The paper
Mackie, I. J., Purdy, G., Machin, S. J., & Lawrie, A. S. (1999). The Sensitivity and Specificity of Commercial Reagents for the Detection of Lupus Anticoagulant Show Marked Differences in Performance between Photo-optical and Mechanical Coagulometers. Thrombosis and Haemostasis. https://doi.org/10.1055/s-0037-1614567

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.