Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 299

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Comparison of Subcutaneous Unfractionated Heparin with a Low Molecular Weight Heparin (Fragmin®) in Patients with Venous Thromboembolism and Contraindications to Coumarin

Monreal, M, Lafoz, E, Olive, A, del Rio, L, Vedia, C·1994·Thrombosis and Haemostasis

Abstract

Summary: Intravenous heparin followed by oral anticoagulant therapy (e. g. with coumarin) is still the most widely used treatment for deep venous thromboembolism. Self-administered subcutaneous injections of heparin have been thought of as a promising alternative to coumarin, but the high doses required for ongoing prophylaxis have raised concerns about the possible development of bone disease. Certainly, long-term heparin therapy has been reported to cause osteoporosis in both laboratory animals and humans. This study aimed to compare the efficacy and safety of unfractionated (UF) heparin with that of a low molecular weight heparin (Fragmin®, Kabi Pharmacia) in the prevention of recurrent deep venous thrombosis (DVT) and pulmonary embolism (PE) in a consecutive series of patients with contraindications to coumarin therapy. The patients comprised 40 men and 40 women, aged between 19 and 92 years (mean age, 68 years). They had all previously been diagnosed as having acute DVT and had been treated with conventional doses of heparin while in hospital. All patients had at least one of the following conditions: recent blood loss (either spontaneous or during admission while receiving heparin therapy); active gastroduodenal ulcer disease; psychological or physical inability or unwillingness to understand and accept the need for regular laboratory monitoring during coumarin treatment; chronic alcoholism; dementia; pregnancy; recent neurosurgery, and pericardial effusion; or were over 80 years of age. They were randomly allocated to receive either UF heparin, 10,000 IU s.c. b.d., or Fragmin®, 5000 IU anti-Factor Xa s. c. b. d., for a period of 3-6 months. Two patients taking UF heparin were readmitted to hospital 2 and 3 months after discharge, owing to symptomatic, scintigraphically proven recurrent PE. No patients receiving Fragmin® had recurrent PE. There were 10 reports of minor bleeding: six in patients receiving UF heparin and four in patients on Fragmin®. Furthermore, there were seven cases of spinal fracture: six in patients on UF heparin, and one in a patient taking Fragmin®. We conclude that fixed doses of both UFH and Fragmin® appear to be quite effective and safe for use in patients with a high risk of bleeding. In our experience, however, UF heparin is associated with an unacceptably high incidence of spinal fracture.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1055/s-0038-1642376

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 299

Metadata

Authors
Monreal, M., Lafoz, E., Olive, A., del Rio, L., & Vedia, C.
Venue
Thrombosis and Haemostasis
Published
1994
Volume
71
Issue
01
Pages
007-011
ISSN
  • 0340-6245 (ISSN-L)
  • 2567-689X
OpenAlex
W4324262398
Cited by
299
References
1
FWCI
11.44
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of Subcutaneous Unfractionated Heparin with a Low Molecular Weight Heparin (Fragmin®) in Patients with Venous Thromboembolism and Contraindications to Coumarin. https://app.cochat.ai/papers/10.1055/s-0038-1642376
The paper
Monreal, M., Lafoz, E., Olive, A., del Rio, L., & Vedia, C. (1994). Comparison of Subcutaneous Unfractionated Heparin with a Low Molecular Weight Heparin (Fragmin®) in Patients with Venous Thromboembolism and Contraindications to Coumarin. Thrombosis and Haemostasis. https://doi.org/10.1055/s-0038-1642376

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.