CoChat

Reversible Inhibition of Human Platelet Activation by Hypothermia In Vivo and In Vitro

Michelson, Alan D, MacGregor, Hollace, Barnard, Marc R, Kestin, Anita S, Rohrer, Michael J, Robert Valeri, C · 1994 · Thrombosis and Haemostasis
Cited by 398

The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.

Abstract

Summary: A hypothermia-induced hemorrhagic diathesis is associated with cardiopulmonary bypass, major surgery, and multiple trauma, but its pathophysiological basis is not well understood. We examined the hypothesis that hypothermia reversibly inhibits human platelet activation in vitro and in vivo. Platelet activation was studied in normal volunteers by whole blood flow cytometric analysis of modulation of platelet surface GMP-140 and the glycoprotein (GP) Ib-IX complex in: a) shed blood emerging from a standardized in vivo bleeding time wound; b) peripheral blood activated in vitro with either thrombin (in the presence of gly-pro-arg-pro, an inhibitor of fibrin polymerization) or the stable thromboxane (TX) A2 analogue U46619. Platelets in peripheral whole blood were activated at temperatures between 22° C and 37° C. the forearm skin temperature was maintained at temperatures between 22° C and 37° C prior to and during the bleeding time incision. Platelet aggregation was studied in shed blood by flow cytometry and in peripheral blood by aggregometry. Generation of TXB 2 (the stable metabolite of TXA 2) was determined by radioimmunoassay. In vitro, hypothermia inhibited both thrombin- and U46619-induced upregulation of GMP-140, downregulation of the GPIb-IX complex, platelet aggregation, and TXB2 generation. These inhibitory effects of hypothermia were all completely reversed by rewarming the blood to 37° C. In vivo, platelet activation was inhibited by hypothermia as shown by 5 independent assays of shed blood: upregulation of GMP-140, downregulation of the GPIb-IX complex, platelet aggregate formation, TXB 2 ggeneration, and the bleeding time. In summary, by a combination of immunologic, biochemical, and functional assays, we demonstrate that hypothermia inhibits human platelet activation in whole blood in vitro and in vivo. Rewarming hypothermic blood completely reverses the activation defect. These results suggest that maintaining normothermia or rewarming a hypothermic bleeding patient may reduce the need for platelet transfusions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1055/s-0038-1642495

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 398

Metadata

Authors
Michelson, A. D., MacGregor, H., Barnard, M. R., Kestin, A. S., Rohrer, M. J., & Robert Valeri, C.
Venue
Thrombosis and Haemostasis
Published
1994
Volume
71
Issue
05
Pages
633-640
ISSN
  • 0340-6245 (ISSN-L)
  • 2567-689X
OpenAlex
W2213866923
Cited by
398
References
20
FWCI
3.89
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.