The DOI matches its Crossref record.
Low Molecular Weight Heparin versus Warfarin in the Prevention of Recurrences after Deep Vein Thrombosis
Abstract
Summary: To evaluate the role of low-molecular weight heparin (LMWH) as an alternative to oral anticoagulants in the prevention of recurrent venous thromboembolism, we compared in a randomized trial conventional warfarin treatment with a three-month course of enoxaparin 4000 anti-Xa units once a day subcutaneously. 187 patients with symptomatic deep-vein thrombosis (DVT), diagnosed by strain-gauge plethysmography plus D-dimer latex assay and confirmed by venography in most cases, were treated with full-dose subcutaneous heparin for ten days and then randomized to secondary prophylaxis. During the 3-month treatment period, 6 of the 93 patients who received LMWH (6%) and 4 of the 94 patients on warfarin (4%) had symptomatic recurrence of venous thromboembolism confirmed by objective testing (p = 0.5; 95% confidence interval [Cl] for the difference, -3% to 7%). Four patients in the LMWH group had bleeding complications as compared with 12 in the warfarin group (p = 0.04; 95% Cl for the difference, 4% to 14%). In the 9-month follow-up period, during which 34 patients on warfarin prolonged treatment for other 3 months and 14 up to one year, 10 patients in the enoxaparin group and 4 patients in the warfarin group suffered a documented recurrence of venous thromboembolism. Of these 14 late recurrences, just one occurred in patients with postoperative DVT. After one year there were 16 recurrences (17%) in the LMWH group and 8 (9%) in the warfarin group (p = 0.07; 95% Cl for the difference, 1% to 16%). These results confirm the potential of LMWH as an alternative to oral anticoagulants in this setting, and suggest to evaluate in a prospective study a slightly higher dose of enoxaparin in patients with postoperative DVT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Kearon (2012) · doi:10.1378/chest.11-2301 · Cited by 6,119
Antithrombotic Therapy for VTE Disease
Kearon, C., Akl, E. A., Ornelas, J., Blaivas, A., Jimenez, D., Bounameaux, H., Huisman, M., King, C. S., Morris, T. A., Sood, N., et al. (2016) · Chest · doi:10.1016/j.chest.2015.11.026 · Cited by 4,830
Lee, A. Y. Y., Levine, M. N., Baker, R. I., Bowden, C., Kakkar, A. K., Prins, M., Rickles, F. R., Julian, J. A., Haley, S., Kovacs, M. J., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa025313 · Cited by 2,534
Antithrombotic Therapy for Venous Thromboembolic Disease
Kearon, C., Kahn, S. R., Agnelli, G., Goldhaber, S., Raskob, G. E., & Comerota, A. J. (2008) · Chest · doi:10.1378/chest.08-0658 · Cited by 1,996
Weitz, J. I. (1997) · New England Journal of Medicine · doi:10.1056/nejm199709043371007 · Cited by 1,533
Metadata
- Authors
- Pini, M., Aiello, S., Manotti, C., Pattacini, C., Quintavalla, R., Poli, T., Tagliaferri, A., & Dettoi, A. G.
- Venue
- Thrombosis and Haemostasis
- Publisher
- Georg Thieme Verlag KG
- Published
- 1994
- Volume
- 72
- Issue
- 02
- Pages
- 191-197
- ISSN
- 0340-6245 (ISSN-L)
- 2567-689X
- OpenAlex
- W131809637
- Cited by
- 218
- References
- 0
- FWCI
- 3.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Low Molecular Weight Heparin versus Warfarin in the Prevention of Recurrences after Deep Vein Thrombosis. https://app.cochat.ai/papers/10.1055/s-0038-1648837
- The paper
- Pini, M., Aiello, S., Manotti, C., Pattacini, C., Quintavalla, R., Poli, T., Tagliaferri, A., & Dettoi, A. G. (1994). Low Molecular Weight Heparin versus Warfarin in the Prevention of Recurrences after Deep Vein Thrombosis. Thrombosis and Haemostasis. https://doi.org/10.1055/s-0038-1648837
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.