Systematic Underestimation of Treatment Effects as a Result of Diagnostic Test Inaccuracy: Implications for the Interpretation and Design of Thromboprophylaxis Trials
The DOI matches its Crossref record.
Abstract
Summary: Many clinical trials that have assessed strategies for the prevention of deep vein thrombosis have employed diagnostic tests that are less accurate than venography. The correct interpretation of these trials has been the subject of considerable debate. This paper attempts to quantify the likely effects of the use of inaccurate diagnostic tests (in particular fibrinogen scanning) on the validity and precision of estimates of treatment effects. It is shown that, if there is no difference in the rate of misclassification of deep vein thrombosis between study and control groups, then treatment effects will tend to be systematically underestimated in trials that only use inaccurate diagnostic tests. However, for trials in which there are no false positive diagnoses, such as those employing venography, the estimate of relative treatment effects will be unbiased. This phenomenon is demonstrated empirically by data from randomised trials of antiplatelet therapy. The implications of these findings are two-fold. First, so long as the accuracy of the test is the same in study and control groups, positive trial results cannot be ascribed to diagnostic test inaccuracy. Second, unbiased estimates of relative treatment effects can be obtained by using cheap, practicable and non-invasive screening tests that are supplemented by venographic assessment of positive test results. This would facilitate the conduct of much larger randomised trials than has generally been possible when mandatory venography was used; if future trials randomised some thousands of patients and employed confirmatory venography then they would provide both unbiased and precise estimates of relative treatment effects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Prevention of Venous Thromboembolism
Geerts, W. H., Pineo, G. F., Heit, J. A., Bergqvist, D., Lassen, M. R., Colwell, C. W., & Ray, J. G. (2004) · Chest · doi:10.1378/chest.126.3_suppl.338s · Cited by 5,895
Prevention of Venous Thromboembolism
Geerts, W. H., Heit, J. A., Clagett, G. P., Pineo, G. F., Colwell, C. W., Anderson, F. A., & Wheeler, H. B. (2001) · Chest · doi:10.1378/chest.119.1_suppl.132s · Cited by 4,373
The Revised CONSORT Statement for Reporting Randomized Trials: Explanation and Elaboration
Altman, D. G., Schulz, K. F., Moher, D., Egger, M., Davidoff, F., Elbourne, D., Gøtzsche, P. C., Lang, T., & for the CONSORT Group (2001) · Annals of Internal Medicine · doi:10.7326/0003-4819-134-8-200104170-00012 · Cited by 3,835
Rodgers, A. (2000) · BMJ · doi:10.1136/bmj.321.7275.1493 · Cited by 2,114
Self-citation
Metadata
- Authors
- Rodgers, A., & MacMahon, S.
- Venue
- Thrombosis and Haemostasis
- Publisher
- Georg Thieme Verlag KG
- Published
- 1995
- Volume
- 73
- Issue
- 02
- Pages
- 167-171
- ISSN
- 0340-6245 (ISSN-L)
- 2567-689X
- OpenAlex
- W2395279856
- Cited by
- 72
- References
- 0
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Systematic Underestimation of Treatment Effects as a Result of Diagnostic Test Inaccuracy: Implications for the Interpretation and Design of Thromboprophylaxis Trials. https://app.cochat.ai/papers/10.1055/s-0038-1653746
- The paper
- Rodgers, A., & MacMahon, S. (1995). Systematic Underestimation of Treatment Effects as a Result of Diagnostic Test Inaccuracy: Implications for the Interpretation and Design of Thromboprophylaxis Trials. Thrombosis and Haemostasis. https://doi.org/10.1055/s-0038-1653746
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.