Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 279

The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.

Ultrasound Reversibly Disaggregates Fibrin Fibers

Braaten, Julie V, Goss, Rachel A, Francis, Charles W·1997·Thrombosis and Haemostasis

Abstract

Summary: Ultrasound accelerates fibrinolysis in vitro and in vivo, primarily through non-thermal mechanisms including cavitation. We have previously observed that ultrasound reversibly increases flow through fibrin gels, a property primarily determined by the structure of the fibrin matrix. Therefore, the effect of ultrasound on the ultrastructure of fibrin gels was examined using scanning electron microscopy. Non-cross- linked fibrin gels were fixed and prepared for microscopy before, during and after exposure to 1 MHz ultrasound, and quantitative analysis of fiber population density and diameter was performed. Gels exposed and fixed in the presence of ultrasound exhibited an increase in density of 65 ± 26% (mean ± SD) at 4 W/cm2 (p <0.000001) accompanied by a decrease in fiber diameter of 27 ± 9% (p <0.000001). Gels fixed 15 min following ultrasound exposure showed no significant change in either density or diameter compared to unexposed gels, indicating that the ultrasound-induced change in fiber structure was reversible. Factor XIII-crosslinked fibrin gels exhibited no change in population density or diameter when exposed to ultrasound. These results indicate that ultrasound exposure causes reversible disaggregation of uncrosslinked fibrin fibers into smaller fibers, an effect that may alter flow resistance and create additional binding sites for fibrinolytic components, improving fibrinolytic efficacy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1055/s-0038-1657688

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 16 references

Cited by

See all 279

Metadata

Authors
Braaten, J. V., Goss, R. A., & Francis, C. W.
Venue
Thrombosis and Haemostasis
Published
1997
Volume
78
Issue
03
Pages
1063-1068
ISSN
  • 0340-6245 (ISSN-L)
  • 2567-689X
OpenAlex
W86398073
Cited by
279
References
16
FWCI
3.36
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Ultrasound Reversibly Disaggregates Fibrin Fibers. https://app.cochat.ai/papers/10.1055/s-0038-1657688
The paper
Braaten, J. V., Goss, R. A., & Francis, C. W. (1997). Ultrasound Reversibly Disaggregates Fibrin Fibers. Thrombosis and Haemostasis. https://doi.org/10.1055/s-0038-1657688

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.