An in vivo Model for the Assessment of Acute Fibrinolytic Capacity of the Endothelium
The DOI matches its Crossref record.
Abstract
Summary: The effects on blood flow and plasma fibrinolytic and coagulation parameters of intraarterial substance P, an endothelium dependent vasodilator, and sodium nitroprusside, a control endothelium independent vasodilator, were studied in the human forearm circulation. At subsystemic locally active doses, both substance P (2-8 pmol/min) and sodium nitroprusside (2-8 μg/min) caused dose-dependent vasodilatation (p <0.001 for both) without affecting plasma concentrations of PAI-1, von Willebrand factor antigen or factor VIII:C activity. Substance P caused local increases in t-PA antigen and activity (p <0.001) in the infused arm while sodium nitroprusside did not. At higher doses, substance P increased blood flow and t-PA concentrations in the noninfused arm. We conclude that brief, locally active and subsystemic infusions of intraarterial substance P cause a rapid and substantial local release of t-PA which appear to act via a flow and nitric oxide independent mechanism. This model should provide a useful and selective method of assessing the in vivo capacity of the forearm endothelium to release t-PA acutely.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Diesel Exhaust Inhalation Causes Vascular Dysfunction and Impaired Endogenous Fibrinolysis
Mills, N. L., Törnqvist, H., Robinson, S. D., Gonzalez, M., Darnley, K., MacNee, W., Boon, N. A., Donaldson, K., Blomberg, A., Sandstrom, T., et al. (2005) · Circulation · doi:10.1161/circulationaha.105.588962 · Cited by 646
Self-citationMills, N. L., Törnqvist, H., Gonzalez, M. C., Vink, E., Robinson, S. D., Söderberg, S., Boon, N. A., Donaldson, K., Sandström, T., Blomberg, A., et al. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa066314 · Cited by 642
Self-citationPersistent Endothelial Dysfunction in Humans after Diesel Exhaust Inhalation
Törnqvist, H., Mills, N. L., Gonzalez, M., Miller, M. R., Robinson, S. D., Megson, I. L., MacNee, W., Donaldson, K., Söderberg, S., Newby, D. E., et al. (2007) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200606-872oc · Cited by 393
Self-citationNewby, D. E., Wright, R. A., Labinjoh, C., Ludlam, C. A., Fox, K. A. A., Boon, N. A., & Webb, D. J. (1999) · Circulation · doi:10.1161/01.cir.99.11.1411 · Cited by 382
Self-citationVenous occlusion plethysmography in cardiovascular research: methodology and clinical applications
Wilkinson, I. B., & Webb, D. J. (2001) · British Journal of Clinical Pharmacology · doi:10.1046/j.0306-5251.2001.01495.x · Cited by 355
Self-citation
Metadata
- Authors
- Newby, D. E., Wright, R. A., Ludlam, C. A., Fox, K. A. A., Boon, N. A., & Webb, D. J.
- Venue
- Thrombosis and Haemostasis
- Publisher
- Georg Thieme Verlag KG
- Published
- 1997
- Volume
- 78
- Issue
- 04
- Pages
- 1242-1248
- ISSN
- 0340-6245 (ISSN-L)
- 2567-689X
- OpenAlex
- W2401280047
- Cited by
- 92
- References
- 0
- FWCI
- 1.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An in vivo Model for the Assessment of Acute Fibrinolytic Capacity of the Endothelium. https://app.cochat.ai/papers/10.1055/s-0038-1657722
- The paper
- Newby, D. E., Wright, R. A., Ludlam, C. A., Fox, K. A. A., Boon, N. A., & Webb, D. J. (1997). An in vivo Model for the Assessment of Acute Fibrinolytic Capacity of the Endothelium. Thrombosis and Haemostasis. https://doi.org/10.1055/s-0038-1657722
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.