Beschleunigt niedrig intensiver, gepulster Ultraschall die Heilung von Skaphoidfrakturen?*
The DOI matches its Crossref record.
Abstract
Since pulsed low-intensity ultrasound (frequency: 1.5 MHz, pulsed by 1 kHz, signal burst width: 200 microseconds, intensity: 30 mW/cm2) has been proven to stimulate fracture healing both clinically and experimentally, our question was whether this therapy also accelerates healing of fresh stable scaphoid fractures. Addressing this question, we did the following prospective randomized clinical trial. Regarding the results of former clinical fresh fracture studies by Heckman and Kristiansen, we postulated that low intensity ultrasound accelerates healing by about 30%. Based on this thesis, we calculated that 30 patients divided into two groups would be necessary to show significant differences between the standard treatment (treated by casting) and an adjunctive ultrasound treatment (treated by casting and additional daily 20 minutes ultrasound treatment) if present. Diagnosis and healing was assessed by CT scans every two weeks. CT's were analyzed by two independent radiologists and one hand surgeon. Furthermore, areas of cancellous bone bridging in correlation to the diameter of the scaphoid was measured in each CT scan. The results showed ultrasounded fractures healing in 43.2 +/- 10.9 days versus 62 +/- 19.2 days in the control group (p < 0.01). Trabecular bridging six weeks after injury showed 81.2% +/- 10.4% healed in the ultrasound-stimulated fractures versus 54.6% +/- 29% in the control (p < 0.05). Our study results confirm those of Heckman and Kristiansen and show a similar acceleration of bone healing. Low intensity ultrasound is successful in accelerating the healing of fresh scaphoid fractures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The Use of Low-Intensity Ultrasound to Accelerate the Healing of Fractures
Rubin, C., Bolander, M., Ryaby, J. P., & Hadjiargyrou, M. (2001) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200102000-00015 · Cited by 412
The effect of low-intensity pulsed ultrasound therapy on time to fracture healing: a meta-analysis.
(2002) · PubMed Central · Cited by 196
Hannemann, P. F. W., Mommers, E. H. H., Schots, J. P. M., Brink, P. R. G., & Poeze, M. (2014) · Archives of Orthopaedic and Trauma Surgery · doi:10.1007/s00402-014-2014-8 · Cited by 151
Low intensity pulsed ultrasound for bone healing: systematic review of randomized controlled trials
Schandelmaier, S., Kaushal, A., Lytvyn, L., Heels-Ansdell, D., Siemieniuk, R. A. C., Agoritsas, T., Guyatt, G. H., Vandvik, P. O., Couban, R., Mollon, B., et al. (2017) · BMJ · doi:10.1136/bmj.j656 · Cited by 128
Ultrasound and shockwave therapy for acute fractures in adults
Searle, H. K., Lewis, S. R., Coyle, C., Welch, M., & Griffin, X. L. (2023) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd008579.pub4 · Cited by 29
Metadata
- Authors
- Mayr, E., Rudzki, M.-M., Rudzki, M., Borchardt, B., Häusser, H., & Rüter, A.
- Venue
- Handchirurgie · Mikrochirurgie · Plastische Chirurgie
- Publisher
- Georg Thieme Verlag KG
- Published
- 2000-03
- Volume
- 32
- Issue
- 2
- Pages
- 115-122
- ISSN
- 0722-1819 (ISSN-L)
- 1439-3980
- OpenAlex
- W296802503
- Cited by
- 113
- References
- 0
- FWCI
- 5.46
- Type
- journal article
- Language
- de
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Beschleunigt niedrig intensiver, gepulster Ultraschall die Heilung von Skaphoidfrakturen?*. https://app.cochat.ai/papers/10.1055/s-2000-19253
- The paper
- Mayr, E., Rudzki, M.-M., Rudzki, M., Borchardt, B., Häusser, H., & Rüter, A. (2000). Beschleunigt niedrig intensiver, gepulster Ultraschall die Heilung von Skaphoidfrakturen?*. Handchirurgie · Mikrochirurgie · Plastische Chirurgie. https://doi.org/10.1055/s-2000-19253
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.