Comparison of Muscle Oxygen Consumption Measured by Near Infrared Continuous Wave Spectroscopy during Supramaximal and Intermittent Pedalling Exercise
The DOI matches its Crossref record.
Abstract
The two purposes of the present study were 1) to determine the oxygen consumption in working skeletal muscle from the oxygenation measured by near-infrared continuous-wave spectroscopy (NIRcws) with the arterial occlusion method during the resting condition, INT(VT), and INT(MAX) and 2) to examine whether the decline rate of oxygenation is related to maximal oxygen uptake. Eight healthy males (aged 19.8 +/- 0.4 yr, height 166.9 +/- 17.4 cm, weight 62.1 +/- 2.5 kg, and maximal oxygen uptake [VO2max] 55.9 +/- 1.9 ml/kg x min(-1)) took part in this study. The oxygenation was measured by NIRcws during the Wingate anaerobic test (WAnT) and two intermittent pedalling exercises of VT (INT(VT)) and maximal (INT(MAX)) work intensity. The decline rates of oxygenation obtained during the resting condition, INT(VT), and INT(MAX) with arterial occlusion were 0.43 +/- 0.05%/sec, 4.94 +/- 0.31%/sec, and 8.16 +/- 0.38%/sec, respectively, and that during the WAnT without arterial occlusion was 8.73 +/- 0.49%/sec. The decline rate of oxygenation during the WAnTwas significantly (p < 0.0001) related to maximal oxygen uptake (VO2max). These findings indicate that O2 is utilized from the early phase, even during a supramaximal pedalling exercise, and that the oxidative metabolic capacity may be a factor contributing to supramaximal exercises. Therefore the arterial occlusion method with NIRcws is suitable for the evaluation of the muscle O2 consumption during exercise noninvasively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hamaoka, T., McCully, K. K., Quaresima, V., Yamamoto, K., & Chance, B. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2805437 · Cited by 329
Self-citationTanimoto, M., & Ishii, N. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00741.2005 · Cited by 269
Logical limitations to the “catastrophe” models of fatigue during exercise in humans
Noakes, T. D., & St Clair Gibson, A. (2004) · British Journal of Sports Medicine · doi:10.1136/bjsm.2003.009761 · Cited by 256
Passive versus Active Recovery during High-Intensity Intermittent Exercises
DUPONT, G., MOALLA, W., GUINHOUYA, C., AHMAIDI, S., & BERTHOIN, S. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000113477.11431.59 · Cited by 159
“it has been found that HbO2 decreases in proportion to the increase in the work rate during continuous exercise (6,16) and that a decreased oxygenation level is significantly lower for intermittent exercises performed at the highest workload (2), it may indicate a faster deoxygenation during IE-AR than during IE-PR.”
BackgroundMuscle Oxygenation Trends During Dynamic Exercise Measured by Near Infrared Spectroscopy
Bhambhani, Y. N. (2004) · Canadian Journal of Applied Physiology · doi:10.1139/h04-033 · Cited by 149
“Bae et al. (2000) also reported a significant correlation (r = 0.976) between the rate of decline in Mox during the Wingate test calculated over 10 sec and the subjects’ VO2max.”
MethodInfluential
Metadata
- Authors
- Bae, S. Y., Hamaoka, T., Katsumara, T., Shiga, T., Ohno, H., & Haga, S.
- Venue
- International Journal of Sports Medicine
- Publisher
- Georg Thieme Verlag KG
- Published
- 2000-04
- Volume
- 21
- Issue
- 3
- Pages
- 168-174
- ISSN
- 0172-4622 (ISSN-L)
- 1439-3964
- OpenAlex
- W2144192351
- Cited by
- 44
- References
- 0
- FWCI
- 1.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of Muscle Oxygen Consumption Measured by Near Infrared Continuous Wave Spectroscopy during Supramaximal and Intermittent Pedalling Exercise. https://app.cochat.ai/papers/10.1055/s-2000-8880
- The paper
- Bae, S. Y., Hamaoka, T., Katsumara, T., Shiga, T., Ohno, H., & Haga, S. (2000). Comparison of Muscle Oxygen Consumption Measured by Near Infrared Continuous Wave Spectroscopy during Supramaximal and Intermittent Pedalling Exercise. International Journal of Sports Medicine. https://doi.org/10.1055/s-2000-8880
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.