Reproducibility of Ultrasound Blood Flow Measurement of the Superior Mesenteric Artery Before and After Exercise
The DOI matches its Crossref record.
Abstract
This study examines the reproducibility of gastro-intestinal blood flow measurements in the superior mesenteric artery (SMA) both before and immediately after exercise with Doppler ultrasound measurements. Twelve well-trained males (mean +/- SD: age 25.9 +/- 3.8 yr; VO2max 4.8 +/- 0.91 x min(-1)) were measured twice (trial 1 and 2) with a 1 week interval before and immediately after 1 hr cycling at 70% VO2max. Duplex scanning was performed with the athletes in supine position immediately after transition from a chair (before exercise) or bicycle (after exercise). The variability of three measurements before exercise was studied within both trials (short-term reproducibility) and the mean pre-exercise values were compared between the trials (long-term reproducibility). In addition, post-exercise measurements were compared in the same way. Reproducibility was tested using the coefficient of variation and Cronbach's alpha. Mean pre-exercise blood flow was 424 +/- 66 ml/min (n = 12) in trial 1 and 375 +/- 38 ml/min (n = 11) in trial 2. Immediately after exercise blood flow had decreased by 49% to 214 +/- 36 ml/min (p <0.01) in trial 1 and by 38% to 234 +/- 36 ml/min (p < 0.01) in trial 2. Blood flow before and after exercise was not significantly different between trials (paired t-test) and therefore reproducible at the group level. Before exercise a good to fair reproducibility was observed both at the short-term (Cronbach's alpha: 0.88 in trial 1, 0.73 in trial 2, n = 11), and at the long-term (alpha = 0.80, n= 11). In contrast, long-term reproducibility immediately after exercise was poor (alpha = -0.99, n = 8 and alpha = 0.36, n = 7 after the first and second cycling period, respectively). In conclusion, duplex scanning of SMA after a sitting-supine transition in well-trained subjects is not a reproducible method at the individual level for intestinal blood flow measurements immediately after exercise.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
van Wijck, K., Lenaerts, K., Grootjans, J., Wijnands, K. A. P., Poeze, M., van Loon, L. J. C., Dejong, C. H. C., & Buurman, W. A. (2012) · American Journal of Physiology-Gastrointestinal and Liver Physiology · doi:10.1152/ajpgi.00066.2012 · Cited by 285
ter Steege, R. W. F., & Kolkman, J. J. (2012) · Alimentary Pharmacology & Therapeutics · doi:10.1111/j.1365-2036.2011.04980.x · Cited by 145
“IGD/PV 8 men 50%, Cycling 40 min 0% Peters etal.(26) DU/SMA 12 men 70%, Cycling 60 min 50% Poor individual reproducibility Rehrer etal.”
Backgroundter Steege, R. W., Geelkerken, R. H., Huisman, A. B., & Kolkman, J. J. (2012) · British Journal of Sports Medicine · doi:10.1136/bjsports-2011-090277 · Cited by 37
Wright, H., Collins, M., Villiers, R. D., & Schwellnus, M. P. (2011) · Clinical Journal of Sport Medicine · doi:10.1097/jsm.0b013e31822148b8 · Cited by 26
Metadata
- Authors
- Peters, H. P., Leeuw, D. D., Lapham, R. C., Bol, E., Mosterd, W. L., & Vries, W. R.
- Venue
- International Journal of Sports Medicine
- Publisher
- Georg Thieme Verlag KG
- Published
- 2001-05
- Volume
- 22
- Issue
- 4
- Pages
- 245-249
- ISSN
- 0172-4622 (ISSN-L)
- 1439-3964
- OpenAlex
- W1983705411
- Cited by
- 20
- References
- 0
- FWCI
- 0.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reproducibility of Ultrasound Blood Flow Measurement of the Superior Mesenteric Artery Before and After Exercise. https://app.cochat.ai/papers/10.1055/s-2001-13811
- The paper
- Peters, H. P., Leeuw, D. D., Lapham, R. C., Bol, E., Mosterd, W. L., & Vries, W. R. (2001). Reproducibility of Ultrasound Blood Flow Measurement of the Superior Mesenteric Artery Before and After Exercise. International Journal of Sports Medicine. https://doi.org/10.1055/s-2001-13811
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.