CoChat

Reproducibility of Ultrasound Blood Flow Measurement of the Superior Mesenteric Artery Before and After Exercise

Peters, H. P., Leeuw, D. de, Lapham, R. C., Bol, E., Mosterd, W. L., Vries, W. R. · 2001 · International Journal of Sports Medicine
Cited by 20

The DOI matches its Crossref record.

Abstract

This study examines the reproducibility of gastro-intestinal blood flow measurements in the superior mesenteric artery (SMA) both before and immediately after exercise with Doppler ultrasound measurements. Twelve well-trained males (mean +/- SD: age 25.9 +/- 3.8 yr; VO2max 4.8 +/- 0.91 x min(-1)) were measured twice (trial 1 and 2) with a 1 week interval before and immediately after 1 hr cycling at 70% VO2max. Duplex scanning was performed with the athletes in supine position immediately after transition from a chair (before exercise) or bicycle (after exercise). The variability of three measurements before exercise was studied within both trials (short-term reproducibility) and the mean pre-exercise values were compared between the trials (long-term reproducibility). In addition, post-exercise measurements were compared in the same way. Reproducibility was tested using the coefficient of variation and Cronbach's alpha. Mean pre-exercise blood flow was 424 +/- 66 ml/min (n = 12) in trial 1 and 375 +/- 38 ml/min (n = 11) in trial 2. Immediately after exercise blood flow had decreased by 49% to 214 +/- 36 ml/min (p <0.01) in trial 1 and by 38% to 234 +/- 36 ml/min (p < 0.01) in trial 2. Blood flow before and after exercise was not significantly different between trials (paired t-test) and therefore reproducible at the group level. Before exercise a good to fair reproducibility was observed both at the short-term (Cronbach's alpha: 0.88 in trial 1, 0.73 in trial 2, n = 11), and at the long-term (alpha = 0.80, n= 11). In contrast, long-term reproducibility immediately after exercise was poor (alpha = -0.99, n = 8 and alpha = 0.36, n = 7 after the first and second cycling period, respectively). In conclusion, duplex scanning of SMA after a sitting-supine transition in well-trained subjects is not a reproducible method at the individual level for intestinal blood flow measurements immediately after exercise.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1055/s-2001-13811

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 20

Metadata

Authors
Peters, H. P., Leeuw, D. D., Lapham, R. C., Bol, E., Mosterd, W. L., & Vries, W. R.
Venue
International Journal of Sports Medicine
Published
2001-05
Volume
22
Issue
4
Pages
245-249
ISSN
  • 0172-4622 (ISSN-L)
  • 1439-3964
OpenAlex
W1983705411
Cited by
20
References
0
FWCI
0.77
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reproducibility of Ultrasound Blood Flow Measurement of the Superior Mesenteric Artery Before and After Exercise. https://app.cochat.ai/papers/10.1055/s-2001-13811
The paper
Peters, H. P., Leeuw, D. D., Lapham, R. C., Bol, E., Mosterd, W. L., & Vries, W. R. (2001). Reproducibility of Ultrasound Blood Flow Measurement of the Superior Mesenteric Artery Before and After Exercise. International Journal of Sports Medicine. https://doi.org/10.1055/s-2001-13811

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.