Introductory Experience with the Continuous Glucose Monitoring System (CGMS®; Medtronic Minimed®) in Detecting Hyperglycemia by Comparing the Self-Monitoring of Blood Glucose (SMBG) in Non-Pregnant Women and in Pregnant Women with Impaired Glucose Tolerance and Gestational Diabetes
The DOI matches its Crossref record.
Abstract
OBJECTIVE: To assess the detection rate of hyperglycemia with a continuous glucose monitoring system compared to a self-monitoring blood glucose profile in non-pregnant, non-diabetic pregnant women, and patients with impaired glucose tolerance or gestational diabetes.. METHODS: Eight non-pregnant (NP) and 56 pregnant women (17 dietary-treated gestational diabetics (GDM), 15 women with impaired glucose tolerance (IGT), and 24 non-diabetic pregnant women (NDP)) underwent a 72-hour measurement with the CGMS (Medtronic Minimed, Northridge, CA, USA). Self-monitored blood glucose measurements, performed 30 minutes before and 120 minutes after each meal, were compared to the duration of hyperglycemia monitored by the continuous glucose monitoring system. RESULTS: No clinically observable infection was found at the subcutaneous tissue where the electrode was placed. A statistically significant difference was found between the groups in body mass index, HbA1c, and in gestational age, but not in age or parity. Using the self-monitored blood glucose (SMBG), 88 % (7/8) of the NP and 54 % (13/24) of the NDP had no measurement above 6.7 mmol/l. However, 17 % (4/24) of the NDP and 40 % (6/15) of the IGT showed more than two measurements above 6.7 mmol/l compared to 24 % (4/17) of the dietary-treated GDM. The differences between these groups were not significant (p = 0.21). The mean durations (+/- SD) of hyperglycemia above 6.7 mmol/l/24 h were: NP 111 +/- 120 min, NDP 138 +/- 120 min, IGT 381.8 +/- 295 min, and GDM 190 +/- 155 min, p = 0.017; above 7.8 mmol/l/24 h NP 24 +/- 49 min, NDP 38 +/- 47 min, IGT 170.7 +/- 190 min, and GDM 64 +/- 88 min, p = 0.016; and above 8.9 mmol/l/24 h NP 9.3 +/- 25 min, NDP 7.5 +/- 14 min, IGT 59 +/- 77 min, and GDM 14 +/- 21 min, p = 0.026. There was no significant difference in the fetal outcome or rate of birth percentiles using the sensor data. CONCLUSIONS: The use of the sensor in pregnant women is unproblematic. a) The CGMS detected more frequent and longer durations of hyperglycemia in GDM compared to non-diabetic pregnant women than the SMBG. b) Women with an IGT exhibited higher glucose levels than patients with gestational diabetes. c) The clinical importance of these hyperglycemic intervals, e.g. with respect to the risk for macrosomia, must be assessed in larger trials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Klonoff, D. C. (2005) · Diabetes Care · doi:10.2337/diacare.28.5.1231 · Cited by 724
Farrar, D., Tuffnell, D. J., West, J., & West, H. M. (2016) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd005542.pub3 · Cited by 194
Patterns of Glycemia in Normal Pregnancy
Hernandez, T. L., Friedman, J. E., Van Pelt, R. E., & Barbour, L. A. (2011) · Diabetes Care · doi:10.2337/dc11-0241 · Cited by 170
“Time to peak glucose concentration after ameal, based on the CGMS articles (22,24,25), was an average of 69.”
MethodYu, F., Lv, L., Liang, Z., Wang, Y., Wen, J., Lin, X., Zhou, Y., Mai, C., & Niu, J. (2014) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2013-4332 · Cited by 162
WEI, Q., SUN, Z., YANG, Y., YU, H., DING, H., & WANG, S. (2016) · Scientific Reports · doi:10.1038/srep19920 · Cited by 99
Metadata
- Authors
- Bühling, K., Kurzidim, B., Wolf, C., Wohlfarth, K., Mahmoudi, M., Wäscher, C., Siebert, G., & Dudenhausen, J.
- Venue
- Experimental and Clinical Endocrinology & Diabetes
- Publisher
- Georg Thieme Verlag KG
- Published
- 2004-12-02
- Volume
- 112
- Issue
- 10
- Pages
- 556-560
- ISSN
- 0947-7349 (ISSN-L)
- 1439-3646
- OpenAlex
- W2070304171
- Cited by
- 50
- References
- 0
- FWCI
- 2.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Introductory Experience with the Continuous Glucose Monitoring System (CGMS®; Medtronic Minimed®) in Detecting Hyperglycemia by Comparing the Self-Monitoring of Blood Glucose (SMBG) in Non-Pregnant Women and in Pregnant Women with Impaired Glucose Tolerance and Gestational Diabetes. https://app.cochat.ai/papers/10.1055/s-2004-830399
- The paper
- Bühling, K., Kurzidim, B., Wolf, C., Wohlfarth, K., Mahmoudi, M., Wäscher, C., Siebert, G., & Dudenhausen, J. (2004). Introductory Experience with the Continuous Glucose Monitoring System (CGMS®; Medtronic Minimed®) in Detecting Hyperglycemia by Comparing the Self-Monitoring of Blood Glucose (SMBG) in Non-Pregnant Women and in Pregnant Women with Impaired Glucose Tolerance and Gestational Diabetes. Experimental and Clinical Endocrinology & Diabetes. https://doi.org/10.1055/s-2004-830399
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.