CoChat

Introductory Experience with the Continuous Glucose Monitoring System (CGMS®; Medtronic Minimed®) in Detecting Hyperglycemia by Comparing the Self-Monitoring of Blood Glucose (SMBG) in Non-Pregnant Women and in Pregnant Women with Impaired Glucose Tolerance and Gestational Diabetes

Bühling, K., Kurzidim, B., Wolf, C., Wohlfarth, K., Mahmoudi, M., Wäscher, C., Siebert, G., Dudenhausen, J. · 2004 · Experimental and Clinical Endocrinology & Diabetes
Cited by 50

The DOI matches its Crossref record.

Abstract

OBJECTIVE: To assess the detection rate of hyperglycemia with a continuous glucose monitoring system compared to a self-monitoring blood glucose profile in non-pregnant, non-diabetic pregnant women, and patients with impaired glucose tolerance or gestational diabetes.. METHODS: Eight non-pregnant (NP) and 56 pregnant women (17 dietary-treated gestational diabetics (GDM), 15 women with impaired glucose tolerance (IGT), and 24 non-diabetic pregnant women (NDP)) underwent a 72-hour measurement with the CGMS (Medtronic Minimed, Northridge, CA, USA). Self-monitored blood glucose measurements, performed 30 minutes before and 120 minutes after each meal, were compared to the duration of hyperglycemia monitored by the continuous glucose monitoring system. RESULTS: No clinically observable infection was found at the subcutaneous tissue where the electrode was placed. A statistically significant difference was found between the groups in body mass index, HbA1c, and in gestational age, but not in age or parity. Using the self-monitored blood glucose (SMBG), 88 % (7/8) of the NP and 54 % (13/24) of the NDP had no measurement above 6.7 mmol/l. However, 17 % (4/24) of the NDP and 40 % (6/15) of the IGT showed more than two measurements above 6.7 mmol/l compared to 24 % (4/17) of the dietary-treated GDM. The differences between these groups were not significant (p = 0.21). The mean durations (+/- SD) of hyperglycemia above 6.7 mmol/l/24 h were: NP 111 +/- 120 min, NDP 138 +/- 120 min, IGT 381.8 +/- 295 min, and GDM 190 +/- 155 min, p = 0.017; above 7.8 mmol/l/24 h NP 24 +/- 49 min, NDP 38 +/- 47 min, IGT 170.7 +/- 190 min, and GDM 64 +/- 88 min, p = 0.016; and above 8.9 mmol/l/24 h NP 9.3 +/- 25 min, NDP 7.5 +/- 14 min, IGT 59 +/- 77 min, and GDM 14 +/- 21 min, p = 0.026. There was no significant difference in the fetal outcome or rate of birth percentiles using the sensor data. CONCLUSIONS: The use of the sensor in pregnant women is unproblematic. a) The CGMS detected more frequent and longer durations of hyperglycemia in GDM compared to non-diabetic pregnant women than the SMBG. b) Women with an IGT exhibited higher glucose levels than patients with gestational diabetes. c) The clinical importance of these hyperglycemic intervals, e.g. with respect to the risk for macrosomia, must be assessed in larger trials.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1055/s-2004-830399

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 50

Metadata

Authors
Bühling, K., Kurzidim, B., Wolf, C., Wohlfarth, K., Mahmoudi, M., Wäscher, C., Siebert, G., & Dudenhausen, J.
Venue
Experimental and Clinical Endocrinology & Diabetes
Published
2004-12-02
Volume
112
Issue
10
Pages
556-560
ISSN
  • 0947-7349 (ISSN-L)
  • 1439-3646
OpenAlex
W2070304171
Cited by
50
References
0
FWCI
2.86
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Introductory Experience with the Continuous Glucose Monitoring System (CGMS®; Medtronic Minimed®) in Detecting Hyperglycemia by Comparing the Self-Monitoring of Blood Glucose (SMBG) in Non-Pregnant Women and in Pregnant Women with Impaired Glucose Tolerance and Gestational Diabetes. https://app.cochat.ai/papers/10.1055/s-2004-830399
The paper
Bühling, K., Kurzidim, B., Wolf, C., Wohlfarth, K., Mahmoudi, M., Wäscher, C., Siebert, G., & Dudenhausen, J. (2004). Introductory Experience with the Continuous Glucose Monitoring System (CGMS®; Medtronic Minimed®) in Detecting Hyperglycemia by Comparing the Self-Monitoring of Blood Glucose (SMBG) in Non-Pregnant Women and in Pregnant Women with Impaired Glucose Tolerance and Gestational Diabetes. Experimental and Clinical Endocrinology & Diabetes. https://doi.org/10.1055/s-2004-830399

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.