CoChat

A Comparison of the Steady-State Pharmacokinetics and Pharmacodynamics of a Novel Rapid-Acting Insulin Analog, Insulin Glulisine, and Regular Human Insulin in Healthy Volunteers Using the Euglycemic Clamp Technique

Becker, R., Frick, A., Burger, F., Scholtz, H., Potgieter, J. · 2005 · Experimental and Clinical Endocrinology & Diabetes
Cited by 53

The DOI matches its Crossref record.

Abstract

Insulin glulisine is a new rapid-acting insulin analog. The aim of this study was to assess the glucodynamic efficacy of insulin glulisine compared with regular human insulin (RHI) using a manual euglycemic clamp technique. Steady-state pharmacokinetics of insulin glulisine, and its cardiac safety (ECG) and tolerability after intravenous administration, were also determined. This was a single center, randomized, open-label, two-way crossover study in healthy male subjects (n = 16). At the treatment visits subjects received an intravenous infusion of the study drug at a rate of 0.8 mU kg (-1) . min (-1) for 2 hours. Individual baseline glucose concentrations were targeted for euglycaemia and maintained with a manual adjusted 20 % glucose solution over the clamp period of a maximum 6 hours. A glulisine-specific antibody was used to quantify glulisine concentrations by radioimmunoassay, while a non-specific insulin antibody and C-peptide based correction for endogenous insulin was used to estimate exogenous human insulin (RHI). At steady state (90 - 120 min), insulin glulisine and RHI had equivalent glucose utilization (GIR-AUC (SS), 209 [corrected] mg . kg (-1) for glulisine, 214 [corrected] mg . kg (-1) for RHI) and infusion rates (GIR (SS), 7.0 and 7.2 [corrected] mg . kg (-1) . [corrected] min (-1) . kg (-1)). Both insulins also presented equal total glucose disposal (GIR-AUC (0 - clamp end), 995 and 1050 [corrected] mg . kg (-1)) and onset of activity within 20 min. Insulin glulisine and RHI showed parallel time concentration profiles with similar distribution and elimination, but the different antibodies employed for radioimmunoassay impeded a quantitative comparison. There were no noteworthy individual or within-group changes in cardiac repolarisation parameters measured by 12-lead ECG during insulin glulisine infusion. In conclusion, insulin glulisine and RHI show similar distribution and elimination profiles and equivalent glucodynamic efficacy on a molar, unit-per-unit basis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1055/s-2005-865637

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Becker, R., Frick, A., Burger, F., Scholtz, H., & Potgieter, J.
Venue
Experimental and Clinical Endocrinology & Diabetes
Published
2005-05-30
Volume
113
Issue
05
Pages
292-297
ISSN
  • 0947-7349 (ISSN-L)
  • 1439-3646
OpenAlex
W1964058889
Cited by
53
References
0
FWCI
3.10
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.