CoChat

Ergometer Error and Biological Variation in Power Output in a Performance Test with Three Cycle Ergometers

Paton, C., Hopkins, W. · 2006 · International Journal of Sports Medicine
Cited by 48

The DOI matches its Crossref record.

Abstract

When physical performance is monitored with an ergometer, random error arising from the ergometer combines with biological variation from the subject to limit the precision of estimation of performance changes. We report here the contributions of ergometer error and biological variation to the error of measurement in a performance test with two popular cycle ergometers (air-braked Kingcycle, mobile SRM crankset) and a relatively new inexpensive mobile ergometer (PowerTap hub). Eleven well-trained male cyclists performed a familiarization trial followed by three 5-min time trials within 2 wk on a racing cycle fitted with the SRM and PowerTap and mounted on the Kingcycle. Mean power output in each trial was recorded with all ergometers simultaneously. A novel analysis using mixed modelling of log-transformed mean power provided estimates of the standard error of measurement as a coefficient of variation and its components arising from the ergometer and the cyclists. The usual errors of measurement were: Kingcycle 2.2 %, PowerTap 1.5 %, and SRM 1.6 % (90 % confidence limits +/- 1.3). The components of these errors arising purely from the ergometers and the cyclists were: Kingcycle 1.8 %, PowerTap 0.9 %, SRM 1.1 %, and cyclists 1.2 % (+/- 1.5). Thus, ergometer errors and biological variation made substantial contributions to the usual error of measurement. Use of the best ergometers and of test protocols that reduce biological variation would improve monitoring of the small changes that matter to elite athletes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1055/s-2005-865781

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 48

Metadata

Authors
Paton, C., & Hopkins, W.
Venue
International Journal of Sports Medicine
Published
2006-06
Volume
27
Issue
6
Pages
444-447
ISSN
  • 0172-4622 (ISSN-L)
  • 1439-3964
OpenAlex
W2045783603
Cited by
48
References
0
FWCI
2.16
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Ergometer Error and Biological Variation in Power Output in a Performance Test with Three Cycle Ergometers. https://app.cochat.ai/papers/10.1055/s-2005-865781
The paper
Paton, C., & Hopkins, W. (2006). Ergometer Error and Biological Variation in Power Output in a Performance Test with Three Cycle Ergometers. International Journal of Sports Medicine. https://doi.org/10.1055/s-2005-865781

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.