Ergometer Error and Biological Variation in Power Output in a Performance Test with Three Cycle Ergometers
The DOI matches its Crossref record.
Abstract
When physical performance is monitored with an ergometer, random error arising from the ergometer combines with biological variation from the subject to limit the precision of estimation of performance changes. We report here the contributions of ergometer error and biological variation to the error of measurement in a performance test with two popular cycle ergometers (air-braked Kingcycle, mobile SRM crankset) and a relatively new inexpensive mobile ergometer (PowerTap hub). Eleven well-trained male cyclists performed a familiarization trial followed by three 5-min time trials within 2 wk on a racing cycle fitted with the SRM and PowerTap and mounted on the Kingcycle. Mean power output in each trial was recorded with all ergometers simultaneously. A novel analysis using mixed modelling of log-transformed mean power provided estimates of the standard error of measurement as a coefficient of variation and its components arising from the ergometer and the cyclists. The usual errors of measurement were: Kingcycle 2.2 %, PowerTap 1.5 %, and SRM 1.6 % (90 % confidence limits +/- 1.3). The components of these errors arising purely from the ergometers and the cyclists were: Kingcycle 1.8 %, PowerTap 0.9 %, SRM 1.1 %, and cyclists 1.2 % (+/- 1.5). Thus, ergometer errors and biological variation made substantial contributions to the usual error of measurement. Use of the best ergometers and of test protocols that reduce biological variation would improve monitoring of the small changes that matter to elite athletes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Validity, Reliability and Sensitivity of Measures of Sporting Performance
Currell, K., & Jeukendrup, A. E. (2008) · Sports Medicine · doi:10.2165/00007256-200838040-00003 · Cited by 768
Yeo, W. K., Paton, C. D., Garnham, A. P., Burke, L. M., Carey, A. L., & Hawley, J. A. (2008) · Journal of Applied Physiology · doi:10.1152/japplphysiol.90882.2008 · Cited by 283
Self-citationWilkerson, D. P., Hayward, G. M., Bailey, S. J., Vanhatalo, A., Blackwell, J. R., & Jones, A. M. (2012) · European Journal of Applied Physiology · doi:10.1007/s00421-012-2397-6 · Cited by 229
“It is noteworthy, however, that although the group mean improvement in 50 mile TT performance did not attain statistical significance, an improvement in completion time of 0.8 % would likely to be practically meaningful during competition (Paton and Hopkins 2006).”
BackgroundInfluentialSwinton, P. A., Hemingway, B. S., Saunders, B., Gualano, B., & Dolan, E. (2018) · Frontiers in Nutrition · doi:10.3389/fnut.2018.00041 · Cited by 228
“For example, offsets in calibration or variation in saddle position may cause observed performances in a cycling-based test, such as the CCT110% to differ from the individuals true score (14).”
BackgroundMcCartney, D., Desbrow, B., & Irwin, C. (2018) · Sports Medicine · doi:10.1007/s40279-017-0800-5 · Cited by 52
Metadata
- Authors
- Paton, C., & Hopkins, W.
- Venue
- International Journal of Sports Medicine
- Publisher
- Georg Thieme Verlag KG
- Published
- 2006-06
- Volume
- 27
- Issue
- 6
- Pages
- 444-447
- ISSN
- 0172-4622 (ISSN-L)
- 1439-3964
- OpenAlex
- W2045783603
- Cited by
- 48
- References
- 0
- FWCI
- 2.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ergometer Error and Biological Variation in Power Output in a Performance Test with Three Cycle Ergometers. https://app.cochat.ai/papers/10.1055/s-2005-865781
- The paper
- Paton, C., & Hopkins, W. (2006). Ergometer Error and Biological Variation in Power Output in a Performance Test with Three Cycle Ergometers. International Journal of Sports Medicine. https://doi.org/10.1055/s-2005-865781
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.